CONVERTING A DIRECT VENT FIREPLACE TO A B-VENTED FIREPLACE:
CONVERTING A B-VENT FIREPLACE TO A DIRECT VENTED FIREPLACE:
Chimney
Connector
Drafthood
Diverter
300° Spill
Switch
Air Channels (x2)
1. Remove the chimney connector, fresh air
cover plates and draft hood cover plate.
2. Install the 300° (149°C) spill switch in the
location provided.
3. Install the two fresh air channels in the
correct locations.
4. Install a new 4’’ chimney liner into the
existing and attach with 3 sheet metal
screws evenly spaced to new 4’’ chimney
connector.
5. Test re the appliance and ensure proper
operation. A venturi adjustment could be
required to achieve an efcient ame.
Improper operation or adjustment could
result in Carbon Monoxide production
causing personal injury or property damage.
Drafthood
Cover Plate
Chimney
Connector
Air Channel
Cover Plate (x2)
1. Remove the chimney connector, 300°
spill switch, two (2) B-vent air channels
and B-vent draft diverter plate.
2. Install the two (2) air channel cover
plates in the locations provided.
3. Install the draft hood cover plate in the
location provided.
4. Install two (2) 3’’ chimney liners in
the existing chimney, securing the
3’’ liners with 3 sheet metal screws
evenly spaced to the new chimney
connector.
5. Test re the appliance and ensure
proper operation. A venturi adjustment
could be required to achieve an
efcient ame. Improper operation
or adjustment could result in Carbon
Monoxide production causing personal
or property damage.
Parts required for conversion
1-Drafthood (2-3’’ dual pipe chimney connector)
2-Air channel cover plates
1-Draft hood cover plate.
Parts required for conversion;
1-300°F (149°C) manual reset spill switch and wires
1-Draft hood (4’’ chimney connection)
2-Air channels
1-Draft hood diverter