Specifications
7
Installation
deciding Where to locate your pellet appliance:
1. Unit must be installed in a masonry fireplace.
2. Do not install the stove in a bedroom or room where people sleep in.
3. Locate the stove in a large and open room that is centrally located in the house.  This will optimize 
heat circulation.
4. Check clearances to combustibles and for the least amount of interference to house framing, plumbing, 
wiring, etc.
5. You can vent the stove with approved flex pipe.
6. This  unit  uses  large  quantities  of  air  for  combustion;  outside  Fresh  Air  connection  is  
. Fresh Air  be connected to all units installed in Mobile and “Air Tight Homes” 
(R2000) or where required by local codes.
7.  Do not obtain combustion air from an attic, garage or any unventilated space. Combustion air may be 
obtained from a ventilated crawlspace. 
8. The  power  cord is  8  feet (2.43  m)  long and may  require a  grounded extension  cord  to  reach the 
nearest electrical outlet.
removing pellet Stove from pallet:
1. Remove the wooden crating surrounding the unit.
2. Remove the cast top, cast sides, cast front, and the cast ash shelf. 
3. Unclip the unit from the lower frame.
4. Slide the unit forward and 
then out.
5. Remove the two top bolts  
on  the  pallet  mounting 
plates as shown in Fig. 3.
6.  Remove  entire  frame  as 
one piece.
Figure 3: Mounting Plates securing stove to pallet