SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE Enviro Maxx OWNER’S MANUAL PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET-BURNING ROOM HEATER. FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. Contact your building or fire officials about restrictions and installation inspection requirements in your area.
Table of Contents Introduction........................................................................................3 Rating Label Location................................................................3 Pellet Quality.............................................................................3 Safety Warnings & Recommendations....................................................4 Operating Instructions..........................................................................
Introduction * This manual is designed for the home owner in conjunction with the technical manual. * RATING LABEL LOCATION: The rating label is located on the inside of the hopper. PELLET QUALITY: Pellet quality is important, please read the following: Your Enviro pellet stove has been designed to burn 1⁄4” (6mm) dia wood pellets only. DO NOT use this appliance as an incinerator.
Safety Warnings & Recommendations Please read this entire Owner’s Manual before installing or operating your Enviro Pellet Stove. Failure to follow these instructions may result in property damage, bodily injury or even death. Any unauthorized modification of the appliance or use of replacement parts not recommended by the manufacturer is prohibited. All national and local regulations and shall be complied with when operating this appliance. Caution: Do not connect to any air distribution duct or system.
Safety Warnings & Recommendations ELECTRICAL: The use of a surge protected power bar is recommended. The unit must be grounded. The grounded electrical cord should be connected to a standard 110-120 volts (3.6 Amps), 60 hertz electrical outlet and also must be accessible. If this power cord should become damaged, a replacement power cord must be purchased from the manufacturer or a qualified Enviro dealer.
Operating Instructions DIMENSIONS & SPECIFICATIONS: 2113/16" (554mm) 1515/16" (404mm) 219/16" (548mm) 263/4" (680mm) 251/16" (637mm) 255/8" (650mm) 4113/16" (1063mm) 411/4" (1047mm) 2313/16" (605mm) Figure 1: Dimensions of Maxx. Table 1: Maxx Specifications. Testing Standard ASTM 1509-04 Frequency 60 Hz Voltage 110 - 120 V Fuel type wood pellets - 6mm (1⁄4”) dia. Current 3.
Operating Instructions CONTROL BOARD FUNCTIONS: 1. AUGER TRIM: Used to change feed rates on LOW ONLY for poorer quality fuels. Push the Auger Trim button until the number 1 and 5 lights appear on the Heat Level Indicator. This will increase the feed rate to 4 seconds ON time Auger pulse. This is done only on LOW to allow the burning of poor quality fuels. Push the button until the number 1 and 4 lights appear, this will reduce the Auger On time to 2 second. This setting is for high-grade fuel only.
Operating Instructions OPERATING YOUR PELLET STOVE: DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN. Keep hopper lid closed except during re-fuelling. CAUTION: When operating during adverse weather, such as high winds or freezing rain, if the unit exhibits dramatic changes in combustion stop using the unit immediately. Watch for blocked exhaust outlet. PRE-BURN CHECK: The burn pot liner holes must be clear and the liner installed properly against the ignitor tube.
Operating Instructions HEAT LEVEL and Fans will drop down to the LOW setting for 30 minutes. If the thermostat contacts close within the 30 minutes, the HEAT LEVEL will return to the previous MANUAL setting. If the thermostat contacts remain open, the stove automatically begins its shutdown routine. The stove will re-light when the thermostat contacts close again. TURNING YOUR PELLET STOVE OFF: • MANUAL and HI / LOW mode: To turn the unit OFF, simply press the ON / OFF button.
Routine Cleaning and Maintenance The following list of components should be inspected and maintained routinely to ensure that the appliance is operating at its optimum and giving you excellent heat value. The appliance, flue gas connector and the chimney flue require regular cleaning. Check them for blockage prior to re-lighting after a prolonged shut down period.
Routine Cleaning and Maintenance DOOR GLASS CLEANING (Weekly) Cleaning of the glass must only be done when stove is cold. Open the door by lifting the handle. The glass can be cleaned by wiping down the outside and inside of the glass with a dry soft cloth. If the glass has build up that can not be removed with only the cloth, clean the glass using paper towel and a gas appliance glass cleaner, this may be purchased through most dealers.
Routine Cleaning and Maintenance EXHAUST VENT (Biannually) This vent should be cleaned every year or after two tons of pellets. We recommend contacting your dealer for professional cleaning. To clean the vent pipe, tap lightly on the pipe to dislodge any loose ash. Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of the vent pipe as possible. FRESH AIR INTAKE (Biannually) Inspect periodically to be sure that it is not clogged with any foreign materials.
Warranty Sherwood Industries Ltd. is the manufacturer of the Enviro line of heating products. At Sherwood Industries, our commitment to the highest level of quality and customer service is the most important thing we do. Each Enviro stove is built on a tradition of using only the finest materials and is backed by our Exclusive Lifetime Limited Warranty to the original purchaser. With Enviro, you’re not just buying a stove, you’re buying a company with years of unequalled performance and quality.
Warranty Exclusions and Limitations: 1. This Warranty does not cover tarnish, discoloration or wear on the plating or paint. 2. This Warranty excludes wear and tear or breakage caused by cleaning, moving or service on log set. 3. A qualified installer must install this stove or fireplace. This Limited Warranty covers defects in materials and workmanship only if the product has been installed in accordance with local building and fire codes; in their absence, refer to the owner’s manual.
Warranty 17. Damage to plated surfaces caused by fingerprints, scratches, melted items, or other external scores and residues left on the plated surfaces from the use of abrasive cleaners or polishes is not covered in this warranty. 18. The Limited Warranty does not cover tarnish, discoloration or wear on the plated surfaces. 19. The paint on the Metal Brick Liner may peel. This is due to the extreme conditions applied to the paint during normal usage. It is not a flaw and is not covered under warranty. 20.
Installation Data Sheet The following information must be recorded by the installer for warranty purposes and future reference.