Specifications

11
4" (100mm)
Exhaust Tube
4" (100mm)
Vent Pipe
Wall Thimble
45
o
Elbow or
Termination Cap
High Temperature RTV
Silicone Required
3" (80mm)
Inlet Tube
Installation
horizontal exhauSt through Wall inStallation:
Vent installation: install vent at clearances specified by the vent manufacturer.
A chimney connector shall not pass through an attic or roof space, closet or similar concealed spaces,
or a floor, or ceiling. Where passage through a wall or partition of combustible construction is desired,
the installation must conform to CAN/CSA-B365 Installation Code for Solid-Fuel-Burning Appliances and
Equipment and with all local regulations, including those referring to regional and national. Only use
venting of L or PL type or corn certified venting if corn will be burned as a fuel with an inside diameter
of 4 inches (100 mm).
1. Place the appliance 15” (37.5 cm) away from the wall. If the stove is to be set on a hearth pad, set
the unit on it.
2. Locate the center of the exhaust pipe on the stove. Extend that line to the wall. Once you have located
the center point on the wall, refer to pellet vent manufacturer installation instructions for correct hole
size and clearance to combustibles.
3. Install the wall thimble as per the instructions written on the thimble. Maintain an effective vapour
barrier in accordance with local building codes.
4. Install a length of vent pipe into the wall thimble. Try not to have joints inside the thimble.
The pipe should install easily into the thimble.
5. Connect the exhaust vent pipe to the exhaust pipe on the stove. Seal the connection with high
temperature silicone.
6. Install the fresh air intake (see Outside Fresh Air COnneCtiOn).
Figure 11: Straight through wall Installation.