Specifications
Troubleshooting
DO NOT:
● Service the stove with wet hands.  The stove is an electrical appliance, which may pose a shock hazard 
if handled improperly. Only qualified technicians should deal with possible internal electrical failures.
● Do not remove from the firebox any screws without penetrating oil lubrication.
WHAT TO DO IF: 
1. The stove will not start. 
2. The stove will not operate when hot. 
3. The exhaust blower will not function normally. 
4. Light # 3 on Heat output bar flashing. 
5. Auger light flashes but auger motor does not turn at all.
6. The 200 °F (93 °C) high limit temperature sensor has tripped. 
7. The convection blower will not function normally. 
8. Ignitor- the Fuel will not light. 
9. Control settings (Heat Level) has no effect on the fire. 
10. The stove keeps going out. 
11 The agitator does not turn.
*NOTE: All troubleshooting procedures should be carried out by qualified technicians or installers. 
1. The stove will not start. 
•  Make sure the stove is plugged in and the wall outlet is supplying power.. 
•  If the Control Board has been placed in the ON /OFF thermostat mode, then turn the thermostat up 
to call for heat. 
•  Ensure the burn pot liner is correctly placed in the burn pot 
•  Check the Heat Level Indicator. - If the # 3 light is flashing (unit may be out of fuel) 
•  Check the Door and Ash Pan door - THEY MUST BE CLOSED TIGHT. 
•  See section 8 “The Fuel will not light”. 
•  Check the fuse on the circuit board. 
•  If the unit still does not start, contact your local service dealer for service.
2. The stove will not operate when hot. 
•  Check the Heat Level Indicator if a fire is not detected or if the fire has gone out the #3 light will flash 
because the Exhaust Temperature Sensor’s contacts have opened. 
•  Check the hopper for fuel. 
•  Incorrect air damper setting. 
  Excessive  air  may  consume  the  fire  too  quickly  before  the  next  drop  of  fuel,  leaving  completely 
unburned fuel in the burn pot liner. 
  Insufficient air may cause the vacuum switch to open or will cause build up, further restricting the air 
flow through the Burn Pot Liner. This in turn will cause the fuel to burn cold and very slowly. Fuel may 
build up and smother the fire. In this case clean the burn pot. 
  NOTE: The unit may require a change to the vent system or installation of fresh air to correct Air to 
Fuel ratio problems if unable to achieve proper damper setting. 
•  Combustion  Blower  failure.  -  The  Combustion  Blower  is  not  turning  fast  enough  to  generate  the 
proper vacuum in the  fire box. Visual  Check – is  the blower motor turning.  See section #3 - The 
Exhaust Blower will not function normally. 
•  Poor  Quality  Fuel  –  Insufficient  energy  in  the  fuel  to  produce  enough  heat  to  keep  the  stove 
burning 
18