Specifications
7
Installation
clearanceS to combuStibleS:
12"
(30.5cm)
4" (10cm)
4" (10cm)
Side Wall
Back Wall
Adjacent Wall
These dimensions are minimum clearances but it is 
recommended that you ensure sufficient room for 
servicing, routine cleaning and maintenance.
Side wall to unit  12 inches  (30.5 cm)
Back wall to unit  4 inches  (10 cm)
Corner to unit  4 inches  (10 cm)
Ceiling height  84 inches  (213 cm)
Figure 3: Maxx-M Clearance to Combustibles. 
thermoStat inStallation:
1.  Install  the  wall  thermostat  (12  or  24  Volt  rated)  in 
a  location  that  is  not  to  close  too  the  unit  but  will 
effectively heat the desired area.
2. Connect the Thermostat or Timer using a 2 x 18 gauge 
wire from the unit to the thermostat.
If the heat in the room becomes to great, the high limit 
switch may turn the stove off and the switch will have to 
be manually reset. To reset the high limit switch, remove 
the  right  cabinet  side.  The  switch  is  found  on  the  air 
jacket.
Remove jumper
wire and install
thermostat wires here.
Figure 5: Thermostat wire placement.
hearth Shield inStallation:
1. Remove  the  right  and  left  hand 
cabinet  sides.  Partially  back  out 
the  two  (2)  T-20  Torx  screws  on 
the back of the each panel and the 
two (2) located on the front inside 
edge below  the louvers and  ash 
shelf.  Pull  the  panel  forward  then 
remove. 
2. Slide the hearth shield into place.
3. Secure  the  shield  to  the  unit  with 
two  (2)  screws  on  each  side  (see 
Figure 4).
4. Re-install the side panels.
Figure 4: Maxx-M Hearth Shield Installation. 