contRoL boaRD functionS:
1. AUGER LIGHT:Thisgreenlightwillflashinconjunctionwiththeaugerpulse.
2. MODE LIGHT:Responsibleforsignalingthestateofthecontrolboard.Whenthelightisflashingthe
stoveisinanautomaticstartmodeorthethermostathascontroloftheunit.Whenthelightissolid,
theHeatLevelSettingcanbealtered.
3. THERMOSTAT SWITCH:Usedtosettheunit’scontrolstooneofthreemodesettings;manual,
high/low,orauto/off.
4. FEED RATE TRIM BUTTON: Usedtochangethefeedratetrimsin¼secondincrementsforall
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
1
2
3
4
5
6
8
7
9
feedsettings.Whenthisbuttonispressed,allthelightwilllightup
on the Heat Output Indicator except for the one that shows the
currentsetting;thedefaultsettingisthenumber4light.Toadjust
thesettingholdtheFeedRateTrimbuttondownandpresstheHeat
Levelupordownbuttonstoadjustthesetting.
5. COMBUSTION BLOWER TRIM BUTTON: Used to change the
CombustionBlowertrimsin5voltincrementsforallfeedsettings
untilitreacheslinevoltage.Whenthisbuttonispressed,allthelight
willlightupontheHeatOutputIndicatorexceptfortheonethat
showsthecurrentsetting;thedefaultsettingisthenumber2light.
ToadjustthesettingholdtheCombustionBlowerTrimbuttondown
andpresstheHeatLevelupordownbuttonstoadjustthesetting.
6. ON/OFF BUTTON:UsedtoturntheunitONandOFF.
7. ROOM AIR FAN ON/OFF BUTTON:Usedtoturnconvectionfan
onoroff.
8. HEAT LEVEL ADJUSTMENT BUTTONS: When pressed, will
changetheheatlevelsettingoftheunitupordown.
9. HEAT OUTPUT INDICATOR: Shows the present heat output
setting.
Figure 2: Circuit Board Control
Panel Decal.
automatic Safety featuReS of youR PeLLet Stove:
A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120°F
(49°C).
B. Thestovehasahightemperaturesafetyswitch.Ifthetemperatureonthehopperreaches200°F
(93°C),theaugerwillautomaticallystopandthestovewillshutdownwhentheexhausttemperature
cools#4lightflashes.Dealerwillhavetoresetthesensor.Ifthishappens,callyourlocaldealertoreset
the200°F(93°C)highlimitswitch. ALSO FIND THE REASONS WHY THE UNIT OVERHEATED.
C) Theunitisequippedwithavacuumswitchtomonitortheventing;ifitbecomesblockedthevacuum
switchwillturnofftheaugerandthe#2lightonthecontrolboardwillflash.
oPeRating youR PeLLet Stove:
PRE-BURN INSTRUCTIONS:Theburnpotlinerholesmustbeclearandthelinerinstalledproperly
againsttheignitortubeforproperoperation.Checkthehopperforenoughpelletstostarttheunit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
Note: Thethermostatmodecanbechangedduringnormaloperation.