Owner`s manual

8
Figure 3: Thermostat Switch in
MANUAL position.
Figure 4: Thermostat Switch in
HIGH/LOW position.
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
1
2
3
4
5
6
8
7
9
Figure 5: Thermostat Switch in
ON/OFF position.
HIGH/LOW MODE:(Requiresathermostat)
INITIAL START-UP:Seemanualmodeabove.
OPERATION:Whenthethermostatcallsforheat(contactsareclosed)
the stove settings are adjustable as per Manual Mode. When the
thermostatcontactsopen,theHEATLEVELandFanswilldropdownto
theLOWsettinguntilthethermostatcontactscloseagain.*TheLOW
heatsettingcanbeadjustedfordifferentfuelqualities(see
Operating
instructiOns - cOntrOl BOard FunctiOns”). The stove will come back to
thepreviousHEATLEVELsettingwhenthethermostatcontactsclose
again.
AUTO/OFF MODE:(Requiresathermostat)
INITIAL START-UP:Seemanualmodeabove.
OPERATION:Whenthethermostatcontactsclose,theunitwilllight
automatically. Once up to temperature,the stove operates the same
asinMANUAL.Whenthethermostatcontactsopen,thestove’sHEAT
LEVELandFanswilldropdowntotheLOWsettingfor30minutes.If
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
1
2
3
4
5
6
8
7
9
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
1
2
3
4
5
6
8
7
9
thethermostatcontactsclosewithinthe30minutes,theHEATLEVELwillreturntothepreviousMANUAL
setting.Ifthethermostatcontactsremainopenthestoveautomaticallybeginsitsshutdownroutine.The
ON/OFFbuttoncanbepressesatanytimethethestovewillimmediatelyshutdown.Thestovewillre-
lightwhenthethermostatcontactscloseagain.
tuRning youR PeLLet Stove off:
MANUALandHI/LOWmode:ToturntheunitOFF,simplypresstheON/OFFbutton.Thiswillstop
thefeedofpellets.Theblowerswillcontinuetooperateandcoolthestovedown.Whencoolenough,
thestovewillturnoff.
AUTO/OFFmode:ToturntheunitOFF,turnthethermostatdownoroff.NOTE:Theunitwillrunon
lowforthree(3)minutesbeforeitturnsoff.
DO NOT unplug unit while Combustion fan is operating.
This may lead to smoke escaping from the stove.
MANUAL MODE:
Allcontrolofcircuitboardfunctionisadjustedatthecircuitboard.
To START: Press the ON / OFF button. The stovewill turn on. The
systemlightwillflash.TheAugerLightwillflashwitheachpulseofthe
auger(theAugerFeedRateispre-programmedduringstart-up).The
HeatLevelIndicatorwillshowtheHeatLevelthatthestovewillrunat
afterstart-upandcanbeadjustedbutthechangewillnottakeaffect
untilthestart-uphasfinished.
Ifthisisthefirsttimetheunithasbeenstartedortheunithasrunout
offuel,theaugerwillneedtobeprimed.Thiscanbedonebyrestartingtheunitfive(5)minutesintoits
start-uporbyputtingasmallhandfullofpelletsintotheburnpot.
To OPERATE: Whenafirehasbeenestablished,theSystemLightwillturnsolid(afterapproximately10
-15minutes)andtheAugerLightwillcontinuetoflashtothecorrespondingHeatLevelsetting.
Theconvectionblower(roomairblower)willturnon.Thespeedofthisbloweriscontrolledbythesetting
oftheheatleveloutputindicator.TheconvectionblowercanbeturnedOFFbydepressingtheconvection
blowercontrolbutton.Forthebestefficiencytheconvectionblowershouldbeleftonatalltimes.
Operating Instructions