Figure 6: Slider/Damper Adjustment Knob.
Figure 7: Efficient Flame.
Operating Instructions
SLiDeR/DamPeR Set-uP:
THE SLIDER / DAMPER MUST BE SET AT TIME OF INSTALLATION.Thisisusedtoregulatethe
airflowthroughthepelletstove.
If,afterlongperiodsofburning,thefirebuildsupandoverflows
theburnpotorthereisabuildupofclinkers,thiswouldbea
signthatthepelletqualityispoor,thisrequiresmoreprimary
air,thesliderdampermustbepulledouttocompensate.Pulling
thesliderdamperoutgivesthefiremoreair.
Theeasiestwaytomakesurethatanefficientflameisachieved
istounderstandthecharacteristicsofthefire.
• A tall, lazy flame with dark orange tips requires more air
–Openslider(pullout)slightly.
• A short, brisk flame, like a blowtorch, has too much air
–Closeslider(pushin)slightly.
•Iftheflameisinthemiddleofthesetwocharacteristicswith
abrightyellow/orange,activeflamewithnoblacktipsthen
theairissetforproperoperation,refertoFigure7.
The combustion exhaust blower is a variable speed blower
controlledbytheheatoutputbutton.Thisblowerwilldecrease
thevacuumpressureinsidethestoveandastheheatoutput
buttonisturneddown.
SPECIAL NOTES:
PelletqualityisamajorfactorinhowthePelletstovewilloperate.
Ifthepelletshaveahighmoisturecontentorashcontentthe
firewillbelessefficientandhasahigherpossibilityofthefire
buildingupandcreatingclinkers(hardashbuild-up).
guiDeLineS foR fine-tuning foR fueL QuaLity:
Duetofuelqualitythesliderdamperandcontrolboardtrimsmayneedtobefine-tuned.
1.Iftheunitbuildsuponallsettings,thesliderdamperrodshouldbepulledoutinsmallincrementsto
givetheunitmoreair.
2.Iftheunithasexcessesashbuild-upinthelineronthelowerfeedsettings,theCombustionBlower
Trimshouldbeincreasedonesettingatatimeuntiltheproblemimproves(FactorySettingis#2).
3.Ifthefireisgoingoutonlowbecausetheairflowistoogreat,theCombustionBlowerTrimcanbe
loweredtothe#1setting.
4.Ifthestovehasexcessesashbuild-upinthelineronthehighersettingstheFeedRateTrimshouldbe
trimmeddownasettingatatimeuntiltheproblemimproves(Factorysettingis#4).
5.Ifyouneedmoreheatandthefuelhaslongpellets,themajorityareover1”(2.5cm)inlength,the
Feed RateTrimcanbe movedup to the #5 setting.NOTE:Onlydo this if thefuelburnswithout
buildingup.