User manual
22
Installation
EXTERIOR MOUNTED EXHAUST BLOWER:
TO SUPPLY POWER TO THE EXHAUST BLOWER:
Install an amour coated electrical cable from the exhaust blower housing, through the wall thimble, and attach to 
the pre-drilled hole in the left hand rear hopper pillar. Hook up to wires from the wiring harness for the exhaust 
blower. All electrical connections must be in accordance with local code requirements (SEE WIRING DIAGRAM).
NOTE:
Ensure that  all  vent  connections  are installed  by  placing  three  screws  evenly  spaced  and  a  small  bead  of  high 
temperature silicone at each chimney connection. Also ensure that all vertical vent sections are properly supported 
and that all clearances to combustibles are maintained in accordance with the vent manufacturer’s specifications.
  
  
    
  
  
 
 
   
 
 
    
 
  
   
Wall framing
Wall thimble
Horizontal frame
for thimble
 
  
   