Instructions / Assembly

Fig. 3
Fig. 1
MODEL ST8L117DMD40
INSTALLATION INSTRUCTIONS
Please read carefully and save these instructions. Failure to
do so may lead to electrical shock or fire, which may cause
injury or death.
________
CAUTION
WARNING RISK OF FIRE: Turn off the main power at the
circuit breaker before installing the fixture, changing lamps,
or performing other maintenance in order to prevent possible
shock.
_________
GENERAL
All electrical connections must be in accordance with local,
and national electrical codes.
Prior to installation remove all protective plastic film covering
from the fixture.
Tools needed for installation: Phillips screwdriver, pliers.
_____________________________
ASSEMBLY AND INSTALLATION
1. Center the fixture on the outlet box. Mark the location of the
keyhole slots of the fixture onto the ceiling. Remove the
fixture from the ceiling.
Note: If the fixture does not sufficiently cover the outlet box,
screw in the semi-circular junction box covers on the back of
the fixture. (Fig. 3)
2. Align the ceiling anchors to the keyhole slot markings on the
ceiling and screw a mounting screw into the center opening.
Then repeat with the second ceiling anchor 88.5 inches
away. (Fig.1)
3. Place the fixture over the outlet box and slide the fixture so
that the ceiling anchor snaps into the narrow ends of the
keyhole slots and is secured flush against the ceiling. (Fig. 2)
4. Pull the power supply wires out from the outlet box.
Connect the black supply wire to the black fixture wire
using a wire nut. Connect the white supply wire to the
white fixture wire using a wire nut. Connect the fixture
ground wire and the supply ground wire together using
a wire nut. Wrap all wire connections with electrical tape
for a more secure connection. (Fig. 4)
________
DIMMING
1. Pull wires from light fixture hole, the dimming wires will be
wrapped around the power supply wires. (Fig. 6) Connect
the purple and pink/grey fixture wires to corresponding
wires of the wall dimmer. (Fig. 5)
For up-to-date list of compatible dimmers, look up the item
number at www.envirolite-LED.com.
Fig. 2
BLACK FIXTURE WIRE BLACK SUPPLY WIRE
WHITE FIXTURE WIRE WHITE SUPPLY WIRE
FIXTURE GROUND WIRE SUPPLY GROUND WIRE
Fig. 4
PURPLE FIXTURE WIRE PURPLE DIMMER WIRE
PINK/GREY FIXTURE WIRE PINK/GREY DIMMER WIRE
Fig. 5
Fig. 6

Summary of content (3 pages)