Step 7:
Install Shuto and Ther-
mosta c Mixing Valves
1
If one is not already installed,
install a manual shuto valve
in the cold water line that
supplies the water heater. Install the
shuto valve near the water heater so
that it is readily accessible. Only use a
full- ow ball or gate valve compa ble
with potable water.
2
Install a Thermosta c Mixing
Valve at each point-of-use
(for example, kitchen sink,
bathroom sink, bath, shower) per the
valve manufacturers instruc ons.
Figure 27 -Install Thermostatic Mixing Valves at
each point where hot water will be used.
WARNING! Even if the water
heater’s thermostat is set to a
rela vely low temperature, hot water
can scald. Install Thermosta c Mixing
Valves at each point-of-use to reduce
the risk of scalding.
3
For water heaters that are fed
by a solar water hea ng
system (or any other pre-
hea ng system), always install a
Thermosta c Mixing Valve or other
temperature limi ng device in the
inlet water supply line to limit water
supply inlet temperature to 120°F.
Solar water hea ng systems can
supply water with temperatures
exceeding 180°F and may result in
water heater malfunc on.
WARNING! Hot water provided by
solar hea ng systems can cause
severe burns instantly, resul ng in
severe injury or death.
Step 8:
Connect the Water
Supply
Note that all piping and components
connected to the water heater must
be suitable for use with potable water.
1
Determine the type of water
pipes in your home. Most
homes use copper water
pipes, but some use CPVC or cross-
linked polyethylene (PEX). Use ngs
appropriate for the type of pipe in
your home. Do not use iron or PVC
pipe.
IF YOU HAVE COPPER PIPES:
If your home has copper water pipes,
you can solder the water pipe connec-
ons or use compression ngs which
don’t require soldering. Compression
ngs are easier to install than solder-
ing pipe. Check with local plumbing
o cials to determine what types of
pipe materials are suitable for your
loca on. Do not use lead-based solder.
NOTICE: Do not solder pipes while
they are a ached to the water heater.
The water heaters inlet and outlet
connec ons contain non-metallic parts
which could be damaged. The proper
way to connect the water heater to
copper water pipes is as follows:
Solder a short length of pipe (about
a foot or so) to a threaded adapter
using only 95/5 n-an mony or
equivalent solder. A ach the thread-
ed adapters to the water heaters
connec ons (using Te on® tape or
pipe joint compound). Connect the
home’s water pipes by soldering,
keeping the connec ons at the water
heater cool with wet rags.
Compression ngs don’t require soldering.