Installation manual

20
ENVISION SERIES INSTALLATION MANUAL
OPERATIONLOGIC
HEATING COOLING
FANON
SL1-IN
ON
SL2-IN
ON
STG1 STG2 STG3 EMERG STG1 STG2
SINGLESPEEDUNITS
Compressor On On On Off On On - - -
RevValve Off Off Off Off On On - - -
Loop Pump On On On Off On On - On -
DHWPump On Off Off Off On On - - -
Secondary1-Out On On On Off On On - - -
EmergLED Off Off Off On Off Off Off - -
T-StatSignal Y1 Y1, Y2 Y1, Y2, W W Y1, O Y1, Y2, O G - -
DUALCAPACITYUNITS
Compressor-Lo On Off Off Off On Off - - -
Compressor-Hi Off On On Off Off On - - -
RevValve Off Off Off Off On On - - -
Loop Pump On On On Off On On - On -
DHWPump On On Off Off On On - - -
Secondary1-Out On On On Off On On - - -
Secondary2-Out Off On On Off Off On - - -
EmergLED Off Off Off On Off Off - - -
T-StatSignal Y1 Y1, Y2 Y1, Y2, W W Y1, O Y1, Y2, O G - -
Operation Logic Data