Specifications
34
ENVISION COMMERCIAL SPECIFICATION CATALOG
Vertical Dimensional Data
Legend
AP = Alternate Service Panel
BP = Blower Service Panel
CP = Control Access Panel
CMP = Compressor Service Panel
2´ [61cm]
Service Access
2´ [61cm]
Service Access
Left Return
(Right Return
opposite side)
2´ [61cm]
Alternate
Service Access
Left Return
(Right Return
opposite side)
D
E
H
F
G
Q
M
N O
O N
B
P
M
A
B
A
T
U
C
R
SS
1.3˝(3.3 cm)
RS
U
T
C
1
2
5
3
4
CP
BP
AP CMP
CMP
BP
CP
AP
AP
FRONT
FRONT
AIR COIL
CMP
Field Installed
Duct Flange
Access Panels
L
Filter Rack
Width
AIR COIL SIDE AIR COIL SIDE
TOP VIEW - RIGHT RETURN
TOP VIEW - LEFT RETURN
RIGHT VIEW - RIGHT RETURN
LEFT VIEW - LEFT RETURN FRONT VIEW
LEFT RETURN
AIR COIL
5
POWER SUPPLY
3/4˝ (19.1 mm)
KNOCKOUT
I
J
K
LOW VOLTAGE
1/2˝ (12.7 mm)
KNOCKOUT
1.00˝ (25.4 mm)
1.6˝ (4.1 cm)
CONDENSATE 3/4"˝
PVC GLUE SOCKET
FRONT
FRONT
BACK
BACK
FILTER RACK CONNECTION FILTER RACK CONNECTION
Overall Cabinet
Water Connections
Return Connection
using std deluxe filter rack (±0.10 in)
Vertical 1 2 3 4 5 I J K
Models A B C D E F G H
Loop
1/2" cond 1/2" cond 3/4" cond L M N O P Q R S T U
Width Depth Height* In Out HWG In
HWG
Out
Cond-
ensate
Water FPT HWG FPT
Low
Voltage
Ext Pump
Power
Supply
Filter Rack
Width
Supply
Width
Supply
Depth
Return
Depth
Return
Height
009-012
in. 22.2 22.5 34.5 5.3 11.9 14.9 8.6 1/2" 1/2" 3.8 9.7 11.7 2.2
2.2
10.0 10.0 6.1 8.8 11.8 1.3 18.1 14.2 1.7
cm. 56.4 57.2 87.6 5.9 13.5 30.2 37.8 21.8 12.7 mm 12.7 mm 9.7 24.6 29.7 5.5 25.4 25.4 15.5 22.4 30.0 3.3 46.0 36.1 4.4
015-018
in. 22.5 26.5 39.4 2.3
2.3
5.3 13.4 16.4 9.6 3/4" 1/2" 5.1 10.8 12.8 14.0 14.0 6.3 7.8 5.9 2.3 22.0 18.0 2.0
cm. 57.2 67.3 100.1 5.8 13.5 34.0 41.7 24.3 19.05 mm 12.7 mm 13.0 27.4 32.5 5.5 35.6 35.6 16.0 19.8 14.9 5.8 55.9 45.7 5.1
Discharge Connection
duct flange installed (±0.10 in)
Electrical Knockouts
022-030
in. 22.5 26.5 48.4 2.3 5.3 13.4 16.4 9.6 3/4" 1/2" 5.1 10.8 12.8 2.2 14.0 14.0 6.3 7.8 5.9 2.3 22.0 26.0 2.0
cm. 57.2 67.3 122.9 5.8 13.5 34.0 41.7 24.3 19.05 mm 12.7 mm 13.0 27.4 32.5 5.5 35.6 35.6 16.0 19.8 15.0 5.8 55.9 66.0 5.1
036-072
in. 25.5 31.2 58.4 3.0 5.3 15.9 18.9 10.6 1" 1/2" 5.6 11.4 13.4 2.2 18.0 18.0 6.6 6.5 3.7 1.6 28.1 34.0 1.7
cm. 64.8 79.2 148.3 7.6 13.5 40.4 48.0 26.9 25.4 mm 12.7 mm 14.2 29.0 34.0 5.5 45.7 45.7 16.8 16.5 9.4 4.1 71.4 86.4 4.3
Condensate is 3/4" PVC female glue socket and is switchable from side to front
Rev.: 05/30/07 B
Vertical unit shipped with 1" (field adjustable to 2") duct collar/filter rack extending from unit 3.25" and is suitable for duct connection.
Discharge flange is field installed and extends 1" (25.4 mm) from cabinet
Top Air Discharge