Datasheet
Damp Heat
Steady State
IEC 60384-14
Test Ca
40 °C / 93% RH / 56 days
No visible damage
I∆C/C
0
I ≤ 5%
I∆ tan δ I ≤ 0.008,
C ≤ 1 µF
I∆ tan δ I > 0.005,
C > 1 µF
Voltage proof
R
INS
≥ 50% of initial limit
Impulse test
Endurance
IEC 60384-14 3 impulses
T
B
/ 1.7 V
R
/ 1000 hours,
1000 V
rms
for 0.1 s every hour
No visible damage
I∆C/C
0
I ≤ 10%
I∆ tan δ I ≤ 0.008,
C ≤ 1 µF
I∆ tan δ I > 0.005,
C > 1 µF
Voltage proof
R
INS
≥ 50% of initial limit
Passive
flammability
IEC 60384-14 Flame applied for a period of time
depending on capacitor volume
B
Active
flammability
IEC 60384-14 20 discharges at 2.5 kV + V
R
The cheesecloth shall
not burn with a flame
B32021 ... B32026
Y2 / 300 V AC
Page 11 of 22Please read Cautions and warnings and
Important notes at the end of this document.