Film Capacitors Metallized Polypropylene Film Capacitors (MKP) Series/Type: Date: B32651 ... B32656 August 2004 © EPCOS AG 2004. Reproduction, publication and dissemination of this data sheet, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.
Metallized polypropylene film capacitors (MKP) B32651 ... B32656 High pulse (wound) Typical applications TV (S-correction/flyback) Electronic ballasts Dimensional drawing Climatic Max.
B32651 ... B32656 High pulse (wound) Overview of available types Lead spacing 10 mm 15 mm Type B32651 B32652 Page 6 7 VR (VDC) 1250 250 400 630 1000 1250 1600 1600 2000 Vrms (VAC) 450 160 200 250 250 500 500 700 700 CR (nF) 1.0 1.5 2.2 3.3 4.7 6.
B32651 ... B32656 High pulse (wound) Overview of available types Lead spacing 22.5 mm 27.5 mm Type B32653 B32654 Page 9 11 VR (VDC) 250 400 630 1000 1250 1600 2000 2000 250 400 630 1000 1250 1600 2000 Vrms (VAC) 160 200 250 250 500 500 700 1000 160 200 250 250 500 500 700 CR (nF) 2.2 3.3 4.7 6.
B32651 ... B32656 High pulse (wound) Overview of available types Lead spacing 37.
B32651 High pulse (wound) Ordering codes and packing units (lead spacing 10 mm) VR VDC1) 1250 Vrms CR f ≤1 kHz VAC nF 2.2 450 3.3 4.7 6.8 Max. dimensions w×h×l mm 4.0 × 9.0 × 13.0 5.0 × 11.0 × 13.0 5.0 × 11.0 × 13.0 6.0 × 12.0 × 13.0 Ordering code (composition see below) B32651A7222+*** B32651A7332+*** B32651A7472+*** B32651A7682+*** Ammo Reel Untaped pack pcs./unit pcs./unit pcs./unit 1000 830 830 680 1700 1300 1300 1100 Further E series and intermediate capacitance values on request.
B32652 High pulse (wound) Ordering codes and packing units (lead spacing 15 mm) VR Vrms CR f ≤1 kHz VDC VAC nF 250 160 400 200 630 250 1000 250 1250 500 150 220 330 470 680 68 100 150 220 330 470 33 47 68 100 150 220 10 15 22 33 47 68 100 6.8 10 15 22 33 Max. dimensions w×h×l mm 5.0 × 10.5 × 18.0 6.0 × 11.0 × 18.0 7.0 × 12.5 × 18.0 8.5 × 14.5 × 18.0 9.0 × 17.5 × 18.0 5.0 × 10.5 × 18.0 5.0 × 10.5 × 18.0 6.0 × 11.0 × 18.0 7.0 × 12.5 × 18.0 8.5 × 14.5 × 18.0 9.0 × 17.5 × 18.0 5.0 × 10.5 × 18.0 5.
B32652 High pulse (wound) Ordering codes and packing units (lead spacing 15 mm) VR Vrms CR f ≤1 kHz VDC VAC nF 3.3 1600 500 4.7 6.8 10 15 2.2 1600 700 3.3 4.7 6.8 10 1.0 2000 700 1.5 2.2 3.3 4.7 Max. dimensions w×h×l mm 5.0 × 10.5 × 18.0 6.0 × 11.0 × 18.0 7.0 × 12.5 × 18.0 8.5 × 14.5 × 18.0 9.0 × 17.5 × 18.0 5.0 × 10.5 × 18.0 6.0 × 11.0 × 18.0 7.0 × 12.5 × 18.0 8.5 × 14.5 × 18.0 9.0 × 17.5 × 18.0 5.0 × 10.5 × 18.0 6.0 × 11.0 × 18.0 7.0 × 12.5 × 18.0 8.5 × 14.5 × 18.0 9.0 × 17.5 × 18.
B32653 High pulse (wound) Ordering codes and packing units (lead spacing 22.5 mm) VR Vrms CR f ≤1 kHz VDC VAC nF 250 160 400 200 630 250 1000 250 1250 500 220 330 470 680 1000 150 220 330 470 680 1000 100 150 220 330 470 33 47 68 100 150 220 22 33 47 68 100 Max. dimensions w×h×l mm 6.0 × 15.0 × 26.5 6.0 × 15.0 × 26.5 7.0 × 16.0 × 26.5 8.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 6.0 × 15.0 × 26.5 6.0 × 15.0 × 26.5 7.0 × 16.0 × 26.5 8.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 11.0 × 20.5 × 26.5 6.0 × 15.
B32653 High pulse (wound) Ordering codes and packing units (lead spacing 22.5 mm) VR Vrms CR f ≤1 kHz VDC VAC nF 6.8 1600 500 10 15 22 33 47 3.3 2000 700 4.7 6.8 10 15 2.2 2000 1000 3.3 4.7 6.8 10 Max. dimensions w×h×l mm 6.0 × 15.0 × 26.5 6.0 × 15.0 × 26.5 7.0 × 16.0 × 26.5 8.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 11.0 × 20.5 × 26.5 6.0 × 15.0 × 26.5 6.0 × 15.0 × 26.5 8.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 11.0 × 20.5 × 26.5 6.0 × 15.0 × 26.5 6.0 × 15.0 × 26.5 8.5 × 16.5 × 26.5 10.5 × 16.5 × 26.5 10.5 × 20.
B32654 High pulse (wound) Ordering codes and packing units (lead spacing 27.5 mm) VR Vrms CR f ≤1 kHz VDC VAC nF 250 160 400 200 630 250 1000 250 1250 500 1600 500 2000 700 1500 2200 3300 4700 1000 1500 2200 3300 680 1000 1500 220 330 470 680 100 150 220 330 47 68 100 150 22 33 47 68 Max. dimensions w×h×l mm 11.0 × 21.0 × 31.5 12.5 × 21.5 × 31.5 15.0 × 24.5 × 31.5 18.0 × 27.5 × 31.5 11.0 × 21.0 × 31.5 12.5 × 21.5 × 31.5 14.0 × 24.5 × 31.5 19.0 × 30.0 × 31.5 11.0 × 21.0 × 31.5 13.5 × 23.0 × 31.
B32656 High pulse (wound) Ordering codes and packing units (lead spacing 37.5 mm) VR Vrms CR f ≤1 kHz VDC VAC nF 850 450 1000 500 1250 500 1600 600 2000 700 220 330 470 680 1000 470 680 1000 220 330 470 680 100 150 220 100 150 220 Max. dimensions w×h×l mm 12.0 × 22.0 × 42.0 12.0 × 22.0 × 42.0 12.0 × 22.0 × 42.0 16.0 × 28.5 × 42.0 18.0 × 32.5 × 42.0 14.0 × 25.0 × 42.0 16.0 × 28.5 × 42.0 20.0 × 39.5 × 42.0 14.0 × 25.0 × 42.0 16.0 × 28.5 × 42.0 18.0 × 32.5 × 42.0 20.0 × 39.5 × 42.0 12.0 × 22.0 × 42.
B32651 ... B32656 High pulse (wound) Technical data Operating temperature range Max. operating temperature Top,max Upper category temperature Tmax Lower category temperature Tmin Rated temperature TR Dissipation factor tan δ (in 10-3) at at 20 °C 1 kHz (upper limit values) 10 kHz 100 kHz Insulation resistance Rins or time constant τ = CR Rins at 20 °C, rel.
B32651 ... B32656 High pulse (wound) Pulse handling capability "dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal voltages, expressed in V/µs. "k0" represents the maximum permissible pulse characteristic of the waveform applied to the capacitor, expressed in V 2/µs. Note: The values of dV/dt and k0 provided below must not be exceeded in order to avoid damaging the capacitor.
B32651 ... B32656 High pulse (wound) k0 values Lead spacing VR Vrms VDC VAC 250 400 630 850 1000 1250 1600 2000 160 200 250 450 250 500 450 500 500 600 700 700 1000 10 mm k0 in V2/µs 25 000 000 15 mm 22.5 mm 27.
B32651 High pulse (wound) Permissible AC voltage Vrms versus frequency f (for sinusoidal waveforms, TA ≤90 °C) For T A >90 °C, please refer to "General technical information", section 3.2.3.
B32652 High pulse (wound) Permissible AC voltage Vrms versus frequency f (for sinusoidal waveforms, TA ≤90 °C) For T A >90 °C, please refer to "General technical information", section 3.2.3.
B32652 High pulse (wound) Permissible AC voltage Vrms versus frequency f (for sinusoidal waveforms, TA ≤90 °C) For T A >90 °C, please refer to "General technical information", section 3.2.3.
B32653 High pulse (wound) Permissible AC voltage Vrms versus frequency f (for sinusoidal waveforms, TA ≤90 °C) For T A >90 °C, please refer to "General technical information", section 3.2.3. Lead spacing 22.
B32653 High pulse (wound) Permissible AC voltage Vrms versus frequency f (for sinusoidal waveforms, TA ≤90 °C) For T A >90 °C, please refer to "General technical information", section 3.2.3. Lead spacing 22.
B32654 High pulse (wound) Permissible AC voltage Vrms versus frequency f (for sinusoidal waveforms, TA ≤90 °C) For T A >90 °C, please refer to "General technical information", section 3.2.3. Lead spacing 27.
B32654 High pulse (wound) Permissible AC voltage Vrms versus frequency f (for sinusoidal waveforms, TA ≤90 °C) For T A >90 °C, please refer to "General technical information", section 3.2.3. Lead spacing 27.
B32656 High pulse (wound) Permissible AC voltage Vrms versus frequency f (for sinusoidal waveforms, TA ≤90 °C) For T A >90 °C, please refer to "General technical information", section 3.2.3. Lead spacing 37.
B32656 High pulse (wound) Permissible AC voltage Vrms versus frequency f (for sinusoidal waveforms, TA ≤90 °C) For T A >90 °C, please refer to "General technical information", section 3.2.3. Lead spacing 37.
B32651 ... B32656 High pulse (wound) Flyback application Permissible voltage and current / waveform Permissible current I pp versus frequency f for a duty cycle of 20% (t 0/t = 0.
B32651 ... B32656 High pulse (wound) Flyback application Permissible current Ipp versus rated capacitance CR Frequency = 15.75 kHz Frequency = 31.
B32651 ...
B32651 ... B32656 High pulse (wound) S-correction application Permissible current Ipp versus rated capacitance CR Frequency = 15.75 kHz Frequency = 31.