Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt values
Lead spacing 10 mm 15 mm 22.5 mm 27.5 mm 37.5 mm
V
R
V
rms
VDC VAC dV/dt in V/µs
250 160
200 120 50
400 200
300 180 100
630 250
400 300 150
850 450
90
1000 250
975 600 300
500
100
1250 450 4000
500
1850 1150 600 140
1600 500
4500 2400 1000
600
210
700
5200
2000 700
8000 7000 2300 200
1000
7500
B32651 ... B32656