Datasheet

Pulse handling capability
"dV/dt" represents the maximum permissible voltage change per unit of time for non-sinusoidal
voltages, expressed in V/µs.
"k
0
" represents the maximum permissible pulse characteristic of the waveform applied to the
capacitor, expressed in V
2
/µs.
Note:
The values of dV/dt and k
0
provided below must not be exceeded in order to avoid damaging the
capacitor.
dV/dt and k
0
values
Lead spacing 10 mm 15 mm 22.5 mm 27.5 mm 37.5 mm 52.5 mm
dV/dt in V/µs 475 340 170 120 80 50
k
0
in V
2
/µs 408500 292400 146200 103200 68800 43200
Impedance Z versus frequency f
(typical values)
B32921C/D ... B32928C/D
X2 / 305 V AC
Page 7 of 17Please read Cautions and warnings and
Important notes at the end of this document.