Datasheet

Specifications and characteristics in brief
Rated voltage V
R
200 ... 450 V DC
Surge voltage V
S
1.15 V
R
(for V
R
250 V DC)
1.10 V
R
(for V
R
400 V DC)
Rated capacitance C
R
68 ... 3300 µF
Capacitance tolerance ±20% M
Dissipation factor tan δ V
R
250 V DC: tan δ 0.15
(20 °C, 120 Hz) V
R
400 V DC: tan δ 0.20
Leakage current I
leak
(5 min, 20 °C)
Self-inductance ESL Approx. 20 nH
Useful life Requirements:
85 °C; V
R
; I
AC,R
> 2000 h C/C ±30% of initial value
40 °C; V
R
; 1.1 I
AC,R
> 100000 h tan δ 3 times initial specified limit
I
leak
initial specified limit
Voltage endurance test Post test requirements:
85 °C; V
R
2000 h C/C ±10% of initial value
tan δ 1.3 times initial specified limit
I
leak
initial specified limit
Vibration resistance
test
To IEC 60068-2-6, test Fc:
Displacement amplitude 0.35 mm, frequency range 10 Hz ... 55 Hz,
acceleration max. 5 g, duration 3 × 2 h.
Capacitor mounted by its body which is rigidly clamped to the work
surface.
Characteristics at low
temperature
Max. impedance ratio
at 100 Hz
V
R
250 V 400 V
Z
-25
°
C
/ Z
20
°
C
3 7
Z
-40
°
C
/ Z
20
°
C
7 14
IEC climatic category To IEC 60068-1:
V
R
250 V DC: 40/085/56 (40 °C/+85 °C/56 days damp heat test)
V
R
400 V DC: 25/085/56 (25 °C/+85 °C/56 days damp heat test)
The capacitors can be operated in the temperature range of
40 °C to +85 °C but the impedance at 40 °C should be taken into
consideration.
Detail specification
Sectional specification
Similar to CECC 30301-806
IEC 60384-4
B43305
Ultra compact 85 °C
Page 3 of 20Please read Cautions and warnings and
Important notes at the end of this document.