Datasheet

Reliability data
Test Standard Test conditions R
25
/R
25
Electrical endurance,
constant at 85 °C
IEC 60738-1 Storage at V
max
T = 85 °C
Test duration : 1000 h
< 25%
Damp heat IEC 60738-1 Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
< 10%
Rapid change
of temperature
IEC 60738-1 T
LCT
= 25 °C, T
UCT
= 125 °C
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, Test Na
< 10%
Vibration IEC 60738-1 Frequency: 10 - 55 - 10 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 · 2 h
Test according to IEC 60028-2-6, Test Fc
< 5%
Bump IEC 60738-1 Pulse shape: half-sine
Acceleration: 50 g
Pulse duration: 1 ms; 6 · 3 pulses
Test according to IEC 60068-2-29
< 5%
Climatic sequence IEC 60738-1 Dry heat: T
UCT
= 125 °C
Test duration: 16 h
Damp heat first cycle
Cold: T
LCT
= 25 °C
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
< 10%
Adhesive strength on
PCB
Shearing of the component soldered on
PCB by a force of 5 N is normal to
components longitudinal axis
No visible
damage
Sensors
Limit temperature sensors, EIA size 0805 A701
Page 4 of 8Please read Cautions and warnings and
Important notes at the end of this document.