Datasheet
Reliability data
Test Standard Test conditions ∆R
25
/R
25
Electrical endurance,
cycling
IEC 60738-1 Room temperature, I
Smax;
V
max
Number of cycles: 100
< 25%
Electrical endurance,
constant
IEC 60738-1 Storage at V
max
/T
op
Test duration : 1000 h
< 25%
Damp heat IEC 60738-1 Temperature of air: 40 °C
Relative humidity of air: 93%
Duration: 56 days
Test according to IEC 60068-2-78
< 10%
Rapid change
of temperature
IEC 60738-1 T = T
LCT
, T = T
UCT
Number of cycles: 5
Test duration: 30 min
Test according to IEC 60068-2-14, Test Na
< 10%
Vibration IEC 60738-1 Frequency range: 10 to 55 Hz
Displacement amplitude: 0.75 mm
Test duration: 3 · 2 h
Test according to IEC 60028-2-6, Test Fc
< 5%
Bump IEC 60738-1 Pulse shape: half-sine
Acceleration: 50 g
Pulse duration: 1 ms; 6 · 3 pulses
Test according to IEC 60068-2-29
< 5%
Climatic sequence IEC 60738-1 Dry heat: T = T
UCT
Test duration: 16 h
Damp heat first cycle
Cold: T = T
LCT
Test duration: 2 h
Damp heat 5 cycles
Tests performed according to
IEC 60068-2-30
< 10%
Bending test EN 130000/4.35 Components reflow-soldered to test board
Maximum bending: 2 mm
< 10%
Overcurrent protection
SMDs, EIA size 1210, 24 V, 63 V and 230 V A606/607, A707, A807, A907
Page 4 of 10Please read Cautions and warnings and