Datasheet

Technical data
Reference standard: IEC / UL 60384-14. All data given at T = 20 °C unless otherwise specified.
Max. operating temperature T
op,max
+110 °C
Dissipation factor tan δ (in 10
-3
)
at 1 kHz 1.0
at 20 °C (upper limit values) 100 kHz 5.0
Insulation resistance R
ins
30 000 M
or time constant τ = C
R
R
ins
at 20 °C, rel. humidity 65%
(minimum as-delivered values)
DC test voltage
4800 V, 2 s
The repetition of this DC voltage test may damage the capacitor. Special care must be taken in
case of use several capacitors in a parallel configuration.
Passive flammability category B
Maximum continuous AC voltage V
AC
750 V (50/60 Hz)
Rated AC voltage (UL60384) 500 V (50/60 Hz)
Maximum continuous DC voltage V
DC
3000 V
T
op
110 °C V
op
= V
AC
(continuously)
temperature
T
op
110 °C V
op
= 1.25 V
AC
(1000 h)
Damp heat test 56 days / 40 °C / 93% relative humidity
Limit values after damp heat test Capacitance change C/C 5%
Dissipation factor change tan δ 0.5 10
-3
(at 1 kHz)
Insulation resistance R
ins
1.0 10
-3
(at 100 kHz)
or time constant τ = C
R
R
ins
50% of minimum
as-delivered values
B81123
Y1 / 500 V AC
Page 5 of 19Please read Cautions and warnings and