Datasheet

4 09/19
Please read Cautions and warnings and
Important notes at the end of this document.
Technical data and measuring conditions
Rated inductance L
R
Measured with impedance analyzer Agilent 4294A or
equivalent at frequency f
L
, 0.1 V, +20 °C
Q factor Q
min
Measured with impedance analyzer Agilent 4294A or
equivalent at frequency f
Q
, +20 °C
Rated temperature T
R
+125 °C
Rated current I
R
Maximum permissible DC with inductance decrease
'L/L
0
d 10% and temperature increase
of d 20 K at rated temperature
Self-resonance frequency f
res,min
Measured with impedance analyzer Agilent E4991A /
network analyzer Agilent E8362B or equivalent at +20 °C
DC resistance R
max
Measured at +20 °C
Solderability (lead-free) Sn95.5Ag3.8Cu0.7: +(245 r5) °C, (5 r0.3) s
Wetting of soldering area t 90%
(based on IEC 60068-2-58)
Resistance to soldering heat +260 °C, 40 s (as referenced in JEDEC J-STD 020D)
Climatic category 55/150/56 (to IEC 60068-1)
Storage conditions Mounted: –55 °C … +150 °C
Packaged: –25 °C … +40 °C, d 75% RH
Weight Approx. 50 mg
B82422A*100SMT inductors, SIMID series
SIMID 1210-100