Datasheet

2-line filters B84113C
SIFI-C for very high insertion loss
Circuit diagram
L
SSB0257-G
LINE LOAD
L’
N N’
Technical data and measuring conditions
Rated voltage V
R
250 V DC/AC, 50/60 Hz
Rated current I
R
Referred to 40 °C ambient temperature
Test voltage V
test
1414 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
Leakage current l
leak
At 230 V AC, 50 Hz
Climatic category (IEC 60068-1) 25/085/21 (–25 °C/+85 °C/21 days damp heat test)
Approvals EN 133200, UL 1283, CSA C22.2 No.8
Characteristics and ordering codes
I
R
A
C
R
L
R
mH
I
leak
mA
Case
style
Approx.
weight
g
Ordering code Mounting plate
for top-hat rail
(ordering code)
V
R
= 250 V DC/AC, 50/60 Hz
3 × 0.47 µF (X2)
+
2 × 4700 pF (Y2)
4 ×
4.7
< 0.5 A
B
K
L
210
210
270
210
B84113C0000A030
B84113C0000B030
B84113C0000K030
B84113C0000L030
C62122A0132B092
6 × 0.47 µF (X2)
+
2 × 4700 pF (Y2)
4 ×
4.7
< 0.5 A
B
L
510
510
510
B84113C0000A060
B84113C0000B060
B84113C0000L060
C62122A0132B095
10 2 × 0.47 µF (X2)
+
2 × 4700 pF (Y2)
4 ×
3.6
< 0.5 A
B
L
690
690
690
B84113C0000A110
B84113C0000B110
B84113C0000L110
C62122A0132B095
2
2
Please read Cautions and warnings and
Important notes at the end of this document.