Datasheet

Surge Arrester T83-A90X
3-Electrode-Arrester Ordering code: B88069X8300B502
AB E / AB PM Issue 04, 23.05.2002
Page 1 of 2
DC spark-over voltage
1) 2) 4)
90
± 20
V
%
Impulse spark-over voltage
4)
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
< 400
< 300
< 450
< 350
V
V
V
V
Nominal impulse discharge current (wave 8/20 µs)
5)
Single impulse discharge current (wave 8/20 µs)
5)
10
15
kA
kA
Nominal alternating discharge current (50 Hz, 1 s)
5)
Alternating discharge current (50 Hz, 9 cycles)
5)
10
40
A
A
Insulation resistance at 50 V
dc
4)
>10
G
Capacitance at 1 MHz
4)
<1.5 pF
Transverse delay time
3)
<0.2 µs
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~10
~1
~60
V
A
V
Weight ~ 2 g
Operation and storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, red
90 YY O
90 - Nominal voltage
YY - Year of production
O-Nonradioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
3)
Test according to ITU-T Rec. K.12
4)
Tip or ring electrode to center electrode
5)
Total current through center electrode, half value through
tip respectively ring electrode.
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845

Summary of content (2 pages)