Datasheet

34
Pleas e read Important notes on page 4 and Cautions and warnings on page 69.
B i tte beachten Sie d i e S e i te 4 Wichtige Hinweise s owi e d i e
Warn- und Sicherheitshinweise auf S e i te 69.
A6/N8 Series
© EPCOS AG 2008
2-Electrode Arresters
2-Elektroden-Ableiter
Medium-duty types
10 kA / 10 A Ø 8 x 6 mm
RAB0165-D
6±0.2
8.7±0.2
ø7.8±0.1
RAB0177-2
+0.1
0.3
ø8
_
+0.2
0.15
6.05
_
RAB0168-3
60+4
ø1
6.05±0.2
+0.1
ø8
0.3
_
RAB0166-L
0.3
+0.1
8
_
9±0.3
8.5±0.3
45˚±3˚
6.05±0.2
9.6±0.3
11.3±0.3
A60-…F N80-… N81-… N81-…SMD
Type N80-A230X
Ordering code B88069X4900C103
N80-C90X A60-A230XF N81-A230X N80-A350X N80-A500X N80-A600X
B88069X4890C103 B88069X2400C103 B88069X4930S102 B88069X4910C103 on request B88069X4990C103
N81-A90X A61-A230XF
1)
N81-A230XSMD N81-A350X N81-A500XG N81-A600X
B88069X4880S102 B88069X2540C102 B88069X4970T352 B88069X4920S102 B88069X4860T502 B88069X2830S102
Nom. DC spark-over 90 230 230 350 500 600 V
voltage V
sdcN
Tolerance of V
sdcN
±220 ±220 ±220 %
Impulse spark-over
voltage
@ 100 V/µs 99% of <500 < 500 < 500 < 700 < 900 < 1100 V
measured values
@ 100 V/µs typical < 450 < 450 < 450 < 650 < 750 < 950 V
values
@ 1 kV/µs 99% of < 600 < 800 < 700 < 900 < 1100 < 1400 V
measured values
@ 1 kV/µs typical < 550 < 700 < 600 < 800 < 900 < 1100 V
values
Nom. alternating 10 10 10 10 10 10 A
discharge current
@ 50 Hz, 1s
Alternating 65 65 65 65 65 65 A
discharge current
@ 50 Hz, 9 cycles
Nom. impulse 10 10 10 10 10 10 kA
discharge current
10 operations 8/20 µs
Single impulse discharge
12 12 12 12 12 12 kA
current, 1 op. 8/20 µs
Impulse discharge cur-1 –1111kA
rent, 1 op. 10/350 µs
Impulse discharge cur-200 on request 200 200 on request on request A
rent, 300 op. 10/1000 µs
Insulation resistance > 10 > 10 > 10 > 10 > 10 > 10 G Ω
Capacitance @ 1 MHz < 1.5 < 1.5 < 1.5 < 1.5 < 1.5 < 1.5 pF
1) Dimensional drawing like A60-A230XF but with lead wires. Total length 60+4 mm.
About packing see page 65.
Ueberspannungsableiter_de-en_2009.qxd 03.11.2008 16:19 Uhr Seite 34