Datasheet
Surge arrester B88069X0780S102
2-electrode arrester EC600X
KB AB E / KB AB PM Issue 06 / 2007-04-19
Please read Cautions and warnings and Page 2 of 4
Important notes at the end of this document.
Features Applications
Standard size
Fast response time
High current rating
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
AC powerline devices
Consumer electronics
Power supply
Electrical specifications
DC spark-over voltage
1) 2)
540 … 720 V
Impulse spark-over voltage
at 100 V/µs - for 99 % of measured values
- typical values of distribution
at 1 kV/µs - for 99 % of measured values
- typical values of distribution
< 1200
< 1000
< 1300
< 1100
V
V
V
V
Service life
10 operations 50 Hz, 1 s 10 A
1 operation 50 Hz, 0.18 s (9 cycles) 65 A
10 operations 8/20 µs 5 kA
1 operation 8/20 µs 10 kA
1 operation 10/350 µs 1 kA
Insulation resistance at 100 V
dc
> 10
GΩ
Capacitance at 1 MHz < 1 pF
Arc voltage at 1 A
Glow to arc transition current
Glow voltage
~ 12
~ 0.8
~ 80
V
A
V
Weight ~ 1.5 g
Operation and storage temperature -40 ... +90 °C
Climatic category (IEC 60068-1) 40/ 90/ 21
Marking, red positive
EC 600 YY O
EC - Series
600 - Nominal voltage
YY - Year of production
O - Non radioactive
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
Terms in accordance with ITU-T Rec. K.12 and DIN 57845/VDE0845