2. Getting started DLS24/xx-460 with 6/4-pole screw terminal block
1. Select modes:
put jumper 1 on 1-2 for internal speed reference (potentiometer 1)
or on 2-3 for external speed reference.
put jumper 2 on 1-2 for 12V motor or on 2-3 for 24V motor.
put jumper 3 on 1-2 for speed reference max. 5V or on 2-3 for 10V
target value input.
put jumper 4 on 1-2 for internal controller enable or 2-3 for external
controller enable (terminal 4).
2. Turn potentiometer 2 (Imax) for current limitation to right position.
3. Turn potentiometer 3 (IxR) compensation to left position.
4. Connection of the control wires see connection diagram, page 7.
5. Connect DC motor to terminals 7 and 8.
6. Connect power supply: to terminal 9 GND, to terminal 10 plus (approx. 12
36 V DC).
7. Now turn on power supply.
8. LED green (power on) illuminates on the pcb.
9. With potentiometer 1 (n ref) the speed reference can be adjust from 0 to
100%, if jumper 1 is put on 1-2.