5.1. Overview DIP switch
Different modes are selectable by using the DIP-switch (mode changes works only, when
the power supply is turned off and on).
DIP 1 Off
Controller enable not inverted (terminals 15 and 16 must be
connected, for working motor in the wanted direction)
DIP 1 ON
Controller enable inverted (terminals 15 and 16 must not be
connected, for working motor in the wanted direction)
DIP 2 Off
ref. Speed enable not inverted (terminal 18 must be connected, for a
working ref. Speed value)
DIP 2 ON
Ref. Speed enable inverted (terminal 18 must not be connected, for a
working ref. Speed value)
DIP 3 Off
Ref. Speed Value 0 to 5V/10V means motor voltage: 0 to +
+12V/+24V (motor voltage)
DIP 3 ON
Ref. Speed value 0 to 5V/10V means motor voltage: -12V/-24V to
+12V/+24V (half speed value -> motor voltage=0VDC)
DIP 4 Off Ramp for motor voltage 1 sec., when DIP5 and DIP 6 are Off
DIP 4 ON Ramp for motor voltage 2 sec., when DIP5 and DIP6 are Off
DIP 5 Off Ramp for motor voltage 1 sec., when DIP4 and DIP6 are Off
DIP 5 ON Ramp for motor voltage 3 sec., when DIP4 and DIP6 are Off
DIP 6 Off Ramp for motor voltage 1 sec., when DIP4 and DIP5 are Off
DIP 6 ON Ramp for motor voltage 5 sec., when DIP4 and DIP5 are Off
DIP 7 Off No motor turn off after 3 sec. motor Overload (on current limit)
DIP 7 ON Motor turn off after 3 sec. motor Overload (on current limit)
DIP 8 Off No function
DIP 8 ON No function