User manual

Seite 4 von 10
Stand: August 2018 Z031-MG
2. Getting started DLR24/20-526 with 15/4-pole spring clamp terminal
1. Select modes:
put jumper 1 on 1-2 for internal speed reference value (potentiometer
1) or on 2-3 for external speed reference
(for internal reference put jumper 2 on 1-2 for value max. 5V DC)
put jumper 2 on 1-2 for reference value max. 5V or on 2-3 for max.
10V DC target value input.
put jumper 3 on 1-2 for 12V motor or on 2-3 for 24V motor.
put DIP switch 1 and 2 ON for inverted enables (no need of connecting
terminal 15, 16 und 18)
put DIP switch 3 to 8 Off
2. Turn potentiometer 2 (Imax) for current limitation to the right position.
3. Potentiometer 3 (IxR) compensation to left position.
4. Connection of the control wires see connection diagram, page 7.
5. Connect DC motor to terminals 3 and 4.
6. Connect power supply to terminal 1 Plus (ca. 10 36V DC), on terminal 2
GND.
7. Now switch on power supply.
8. LED green (power on) illuminates on the pcb.
9. With potentiometer 1 (n ref) the speed reference value can be adjust from
0 to 100%, if jumper 1 was put on 1-2.