EasyPlus mini R2N Self-Monitoring Blood Glucose System User’s Manual Please read this User’s Manual thoroughly before using your blood glucose meter.
Dear EasyPlus mini R2N SMBG System Owner, Thank you for using the EasyPlus mini R2N Self-Monitoring Blood Glucose (SMBG) System. We designed this system to be dependable, easy-to-use, compact, lightweight and portable to help you monitor your blood glucose on a regular basis. Please read this manual thoroughly before you begin testing. This manual provides you and your diabetes care team with important information and step-by-step direction to use the EasyPlus mini R2N Self-Monitoring Blood Glucose System.
Standard Accessories Your new EasyPlus mini R2N Blood Glucose meter and accessories work together to measure the amount of glucose in your blood.
Why is it so important to test blood glucose regularly? Testing your blood glucose regularly can make a big difference in how you manage your diabetes every day. We’ve made this SMBG system as simple as possible to help you use it regularly. Your meter is easy to use, and you can adjust the lancing device for your comfort. Do you need Help? If you have questions or need assistance, please call the Customer Care Service toll-free at 1-866-203-2761(Eastern Time, Mon-Fri 9:00AM~5:00PM).
Important Information About Your New Meter EasyPlus mini R2N blood glucose meter is designed and approved for testing fresh capillary whole blood samples from your fingertip and forearm. The meter is for in vitro diagnostic use ONLY(for testing outside the body). It should not be used to diagnose diabetes. EasyPlus mini R2N blood glucose meter can only be used with EasyPlus mini R2N Blood Glucose Test Strips. Other test strips will give inaccurate results.
Warning for potential biohazard: Healthcare professionals using this system on multiple patients should be aware that all products or objects that come in contact with human blood, even after cleaning, should be handled as if capable of transmitting a viral disease. Consult with your healthcare professional before testing on your forearm. Do not touch the strips with wet hands. Do not use expired strips (the expiration date is shown on the bottle.) Do not bend, cut or twist the strips.
Health-Related Information If you are experiencing dehydration, frequent urination, low blood pressure, shock or hyperosmolar hyperglycemic nonketotic coma (HHNK), you may get a test result that is lower than what your blood glucose really is. If you think you are dehydrated, call your doctor right away.
Table of Content Chapter 1: Understanding Your Meter ….......................................................................................................10 The EasyPlus mini R2N Blood Glucose Meter …......................................................................................10 Setting The Time And Date ........................................................................................................................12 Setting Hypo And Hyper ................................................
Symptoms Of High Or Low Blood Glucose …................. ..........................................................................32 Comparing Your Meter Result To Lab Results ….....................................................................................33 Chapter 4: Meter Memory, Setup …...............................................................................................................34 Memory, Storing Test Results …......................................................................
Chapter 1: Understanding Your Meter The EasyPlus mini R2N Blood Glucose Meter The Overview of the Display month and date Time Test result Error Application of blood or E Control Solution A B C D F Control solution test G Hypo H Hype I Test records J Insert test strip K Glucose unit L Thermometer M Batteries status Meaning Show the moment of month and date. Show the moment of time. Show the test result. The meter system is in fault. Test your level of blood glucose.
The Overview of the Meter: A. Anti-Slippery Ring B. Battery cover C. Display D. Manufacturer information E. Serial number F. Strip slot The Overview of the Test Strip: A. Blood collection area B. Reaction area C. Holding area D. Strip insert direction E.
Setting The Time and Date—First Time Use Setting the current time and date in your meter is important if you use the meter memory. 1. Press “W ”until turning the meter on. Press “W ” once again and release to enter the setting mode. 2. The last 2-digits of the year flash at the center of the display. Press “X ” to adjust the year and Press “W ” to confirm the setting. 3. Repeat step 2 to set the date and time. The flashing field is the one you are currently setting.
Setting Hypo and Hype 4. Press “X ” to adjust value of hypo and Press “W ” to confirm the setting. 5. Press “X ” to adjust value of hype and Press “W ” to confirm the setting. 6. When setting is finished, the display will be back to the testing mode of flashing strip. Note: Hypo setting are from 60 mg/dL to 80 mg/dL; Hype setting from 150 mg/dL to 600 mg/dL.
Checking Your Meter A new check strip is included with your meter. The check strip tests only the function of the meter and not the test strip’s ability to render a result (which would need a control solution), or the accuracy of the system as a whole. 1. Make sure your check strip is inserted. The meter will turn on automatically. 2. The screen displays "OK". Note: 3. Remove the check strip and the meter will turn off automatically. Store the check strip in a safe place.
Using EasyPlus mini R2N Blood Glucose Test Strip Use only with EasyPlus mini R2N Blood Glucose Meter. Keep the test strips in their original bottle. Close the bottle tightly right away, after you take a test strip out. This keeps the test strips dry. Use the test strip within three minutes after taking it out of the bottle. The strip is for single use only. Do not reuse it. Record the date you open the test strip bottle. Be sure to check the expiration date on the test strip bottle.
Chapter 2: Control Solution Testing Why Run A Control Solution Test We recommend that you run the EasyPlus mini R2N Normal and High Control Solutions. Such test will let you know that your meter and test strips are working properly to give reliable results. You should run the control solution tests when: You use the EasyPlus mini R2N Blood Glucose Meter for the first time. You open a new bottle of test strips. You think the meter or test strips may be working incorrectly. You drop the meter.
About The Control Solutions Use only with EasyPlus mini R2N test strips. Write the date you opened the bottle on the bottle label. The control solutions are good for three months from the date the bottle is opened or until the expiration date on the bottle, whichever comes first. Do not uses control solutions that are past the expiration date. The control solutions can stain clothing. If you spill them, wash your clothes with soap and water. Close the bottle tightly after every use.
Running A Control Solution Test 1. Put a test strip into the meter in the direction of the arrow. 2. Press “X” for 1 seconds to 5. Squeeze the bottle until a tiny drop forms at the tip of the bottle. set “ ”. Touch the drop to the Blood collection area at 3. Place the meter on a flat surface, like a table. the end of the test strip. 4. Remove the control Do not put control solution on top of the solution bottle cap and test strip.
6. A result appears on the display. Don’t remove the test strip yet. Check if the reading falls within the range printed on the test strip bottle. 7. Remove the test strip and throw it away after you have compared the reading to the range printed on the test strip bottle. Understanding Control Test Results The label on your test strip bottle shows the acceptable ranges for the Control Solutions. The result you get should be inside this range.
When the control result is inside the range on the test strip bottle, your test strips and your meter is working properly. If your control result is not inside the acceptable range (printed on your test strip bottle), here are some things you can do to solve the problem: Note: Control Solution values will be included in the memory and averages, if a flag icon of “ set.
Troubleshooting Checks Action 9 Was the test strip exposed to open air for a long period of time? Repeat the control test with properly stored strips. 9 Was the test strip bottle capped tightly? This will humidify strips inside. Replace the test strips. 9 Was the meter functioning well? You can use the check strip to verify the meter’s functions. 9 Are the control solutions expired or contaminated? Replace with a new control solution to check the performance of SMBG system.
Chapter 3: Testing Your Blood Glucose Using The Lancing Device The best depth setting is the lowest number that draws enough blood for a test. Try different settings to find the one that’s right for you. Please do not share your lancing device with anyone. And always use a new, sterile lancet. Lancets are for one time use only. Note: Used test strips and lancets are considered bio-hazardous waste in accordance with U.S. local regulations and should be handled as if capable of transmitting infection.
Inserting A Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use. 1. Take the cap off. 2. Insert the lancet into the lancing device firmly then twist off the protective cover. 3. Recap the front cap.
4. Select the desired penetration depth. 5. Pull on the sliding barrel of the lancing device until it clicks and then release. Now the lancing device is ready. Do not prick your finger until your meter and strip are prepared. 6. Set the lancing device aside until later in the test. Note: Select 1-3 for soft or thin skin, 4-5 for average, and 6-8 for thick or calloused skin.
Running A Blood Glucose Test With Blood From Your Fingertip 1. Wash your hands with soap and warm water. Rinse and dry thoroughly. 2. Put a test strip into the meter in the direction of the arrow. The meter turns on. Note: If a flag icon of “ ” is set, press “X” for 1 seconds to cancel the setting of control solution test. 3. Swab the blood collection area on your finger with an alcohol swab. Please wait at least 5 seconds until the intended area is dry and clean before sampling the blood. 4.
5. When the blood drop flashes on the display, obtain a drop of blood from your fingertip. 6. Gently squeeze your finger to assist the flow of blood. This helps you get a blood drop. Touch the drop to the tip of the transparent window of the test strip. Do not put blood on top of the strip. Be sure to get enough blood on the strip’s reaction zone. Otherwise, an inaccurate reading may result. 7. The meter will beep when enough blood has entered the strip’s reaction zone.
Alternative Site Testing (AST) Understanding Alternative Site Testing What is AST? Besides the fingertip, you can test the forearm. What is the advantage of AST? You have the option of testing other places on your body besides the fingertip. Consult your health care professional before you begin using the forearm for testing. Blood glucose test results obtained from your forearm may differ significantly from fingertip samples.
Fingertip test only: If sick If blood glucose is low After exercising Two hours or less after eating When basal insulin is most active What After NOT injecting to do: rapid-acting insulin (two hours or less) If the blood glucose test result does not match how you feel, do a fingertip test to confirm the result again. Do NOT change your treatment just because of an alternate site result, do a fingertip test to confirm the result.
Running A Blood Glucose Test With Blood From Your Forearm 1. Massage the puncture area of forearm for a few seconds. 2. Change the gray cap into limpid cap for AST testing. 3. Press and hold the device with one clear adjustable tip against the forearm. 4. Press the trigger button to activate the lancing device.
Discarding Used Lancets 1. Take the adjustable cap off. Without touching the used lancet, stick the lancet tip into its protective cover. Grip the lancet carrier firmly and pull the lancet safely out. 2. Discard the used disposable lancet into a container for sharp or biohazard material.
Expected Values The EasyPlus mini R2N Blood Glucose test strips are whole-blood referenced and calibrated for easier comparison to lab results. The normal fasting blood glucose range for an adult without diabetes is 70~110 mg/dL. Two hours after meals, the blood glucose range for an adult without diabetes is less than 120 mg/dL. For people with diabetes: please consult your doctor for the blood glucose range appropriate for you.
Symptoms Of High Or Low Blood Glucose Being aware of the symptoms of high or low blood glucose can help you understand your test results and decide what to do if they seem unusual. Here are the most common symptoms: 1 Below 60 mg/dL 2 Greater than 240 mg/dL What It Means: The test result is higher than reference range. (70~110mg/dL) What It Means: The test result is lower than reference range.
Comparing Your Meter Result To A Lab Result The meter is equivalent to whole blood (as noted on the page 31 of the user’s manual). A common question is how the blood glucose results on your meter compare to the lab results. Your blood glucose can change quickly, especially after eating, taking medication, or exercising. If you test yourself in the morning, then go to the doctor’s office for a blood glucose test. The results will probably not match, even if you are fasting.
Chapter 4: Meter Memory, Setup Memory, Storing Test Results Your meter stores a maximum of 480 test results with the time and date of the test. You can review them at any time. When the memory is full, the oldest result is dropped as the newest is added, so it is very important to have the correct time and date set in the meter. Note: 1. Do not change your therapy based on one individual result in memory. 2. The memory is not lost when you replace the battery.
Viewing Test Results 1. Press “X” to view the last test result. 2. Press “W” to view the previous results in order from the latest to the earliest. 3. Press “X” once again to view averages of 7-day test result. 4. Press “W” to review averages of 14-day, 30-day and 90-day test results. 5. Press “X” to be back to the testing mode of flashing strip.
Setting The Alarm The meter can set up to 4 alarms, allowing you to control your test times according to your requirements. 1. Press “X” for 5 seconds and enter the setting mode of alarm. 2. Press “W” to set “On” for the first alarm. 3. Press “W” to adjust time and press ” X” to confirm the setting (24-hour clock). 4. Press “X” to confirm the first 5. Repeat step 1 to 4 to set other 3 alarm. If you don’t want to setting and then get into the turn on the alarm at all, turn second one.
Chapter 5: Maintenance and Troubleshooting Installing Batteries The meter uses two batteries of CR2032 Lithium Cell 3V. Batteries will normally last for over 2000 tests. Other types of CR2032 Cell 3V batteries are also acceptable, yet the capacity of test times may differ. Install the batteries when you first use the meter or replace with new batteries when the "LP" message and the low battery symbol appear on the display. Low battery symbol Note: 1.
Cleaning Your Meter Caring for your EasyPlus mini R2N SMBG system does not require special cleaning. Please keep the meter free of dirt, dust, bloodstain, and water stains. Follow these guidelines carefully to help you get the best performance possible: Do: Do Not: Make sure the meter is turned off. Get any moisture in the test strip slot. Gently wipe the meter’s surface with a soft cloth slightly dampened. Spray any cleaning solution directly onto the meter.
Maintenance and Testing Your meter needs little or no maintenance with normal use. It automatically tests its own systems every time you turn it on and lets you know if something is wrong. (See "Screen Messages" and what to do about them.) To make sure the display is working properly, turn off the meter. Press and hold “W” or “X” to see the complete display. All the indicators should be clear and look exactly like the picture to the left.
Screen Messages And Troubleshooting Never make treatment decisions based on an error message. If you have any concerns, call our Customer Service Toll-Free: 1-866-203-2761(Eastern Time, Mon-Fri 9:00AM~5:00PM). Humidified / Used strips Action: Replace with a new strip. Low power Action: Replace with new batteries. System fault Action: Replace the batteries first. If 001 ERROR appears again, please call Customer Service toll-free 1-866-203-2761. System fault Action: Replace the batteries first.
The "Ht" and thermometer icon appears. Temperature is too high, outside the required range of 50°F ~104°F (10°C ~40°C). This alerts users that an incorrect result may occur if the test continues. Action: Relocate the meter to a location with temperature between 50°F ~104°F (10°C ~40°C). The "Lt" and thermometer icon appears. Temperature is too low, outside the required range of 50°F ~104°F (10°C ~40°C). This alerts users that an incorrect result may occur if the test continues.
Chapter 6: Technical Information Specifications Brand name EasyPlus mini R2N Blood Glucose Meter Range 20~600 mg/dL Response time 5 seconds Memory sets 480 test results Operating condition Temp. 50°F ~104°F (10°C ~40°C) Relative Humidity R.H. ≦ 90% Blood sample 0.6 μL Fresh blood from fingertip or forearm Hematocrit (Hct) 20~60% Power CR2032 Lithium Cell 3V (2 pcs) Battery life Over 2000 tests Display dimension 2.0 x 1.3 (inches) Device dimension H × W × D 3.5 x 2.1 x 0.
Limitation The test strips are used for fresh capillary whole blood samples. 1. DO NOT use neonate blood sample. 2. Extreme humidity may affect the results. A relative humidity greater than 90﹪may cause incorrect results. 3. The system should be used at a temperatures between 50℉ and 104℉ (10℃ and 40℃). Outside this range, the system may get incorrect results. 4. DO NOT reuse the test strips. The test strips are for single use only. 5.
10. Critically ill patients should not be tested with home-use blood glucose meters. 11. Interfering Substances depend on the concentration. The below substances up to the test concentration will not affect the test results.
Device Information EasyPlus mini R2N SMBG System, EasyPlus mini R2N Blood Glucose Test Strips, EasyPlus mini R2N Blood Glucose Meter, EasyPlus mini Normal Control Solution, EasyPlus mini High Control Solution. Reference: * American Diabetes Associations: Standards of Medical Care for Patients with Diabetes Mellitus, Diabetes Care, 25(2002), p.S37 Manufacturer: EPS BIO TECHNOLOGY CORP. 2F, No.49-2, Lane 2, Guang-Fu Rd., Sec.
Lancing Device Meets the requirements of MDD 93/42/EEC Manufacturer: STAT MEDICAL DEVICES INC. 1835 N.E. 146th Street, North Miami, FL33181, USA TEL:(001) 305-945-0011 FAX:(001) 305-949-7370 E-mail:stat@statdevices.com Lancet Meets the requirements of MDD 93/42/EEC Manufacturer: SAE HAN MEDICAL CORP. # 700-113 PUB GOT-DONG, IL SAN-GU, GOYANG-CITY, KYUNGGI-DO, KOREA TEL:82-31-923-4330 FAX:82-31-923-4331 E-mail:saehan@saehanmed.com References 1. 2. Stedman, Thomas Lathrop.