Note: The wire size is only for reference. If there is a long distance between the
PV array and the controller or between the controller and the battery, larger wires
can be used to reduce the voltage drop and improve performance.
2.4 Mounting
CAUTION: The controller requires at least 150mm of clearance
above and below for proper air flow. Ventilation is highly
recommended if mounted in an enclosure.
WARNING: Risk of explosion!
Never install the controller in a sealed enclose with flooded
batteries! Do not install in a confined area where battery gas can
accumulate.
WARNING: Risk of electric shock!
Exercise caution when handling solar wiring. The solar PV array
can produce open-circuit voltages in excess of 150 V when in
sunlight. Pay more attention to it.
ATTENTION: Le contrôleur Tracer nécessite au moins un espace
libre de 150mm au dessus et en dessous pour une circulation
correcte de l'air. Une ventilation est hautement recommandée en
cas d'installation dans un boitier.
AVERTISSEMENT : Risque d‘explosion !
N'installez jamais le Tracer dans un boitier fermé avec des
batteries noyées! N'installez pas dans un espace confiné des
gaz de batterie peuvent s'accumuler.
AVERTISSEMENT: Risque d'électrochoc!
Faites attention lors de la manipulation des connexions solaires.
La matrice PV solaire peut produire des tensions supérieures à
150V, à la lumière du soleil. Soyez particulièrement attentif à cela.