Service manual

1.2.3 Resistance to Electric Noise
Static electricity: Panel - 10 KV
Metal - 7 KV
1.2.4 Environmental Conditions
Temperature
Operating: 5 to 35° C (41 to 95° F)
Storage: –20 to 60° C (–13 to 140° F)
Humidity
Operating: 10 to 80 %, no condensation
Storage: 20 to 85 %, no condensation
1.2.5 Reliability
Main unit: MCBF 100,000 cycles
1.2.6 Operating Conditions
Dust: Ordinary office or home conditions.
Avoid placing in an extremely dusty environment.
Illumination: Avoid operation under direct sunlight or near a strong light source.
1.2.7 Documents
Refractive type: Documents with smooth surfaces, such as printing and photographs.
1.2.8 Size of Original for Scanning
Dimensions: 216 mm horizontal × 297 mm vertical
(8.64 inches horizontal × 11.88 inches vertical)
1.2.9 Physical Dimensions and Weight
Dimensions (W × D × H): 297 mm × 443 mm × 87 mm (11.7 × 17.4 × 3.4 inches)
Weight: Approx. 5 kg (11.0 lb.)
216 mm (8.64 inches)
297 mm
(11.88 inches)
Origin
Figure 1-2. Maximum Size of Original for Scanning
Product Description GT-5000 / Action Scanner II Service Manual
1-4 Rev. A