Service manual

REV.-A
Flowchart (1) abnormal operation at power on
WARNING
Do not touch the heat sink attached to the FET
(Ql)
when the printer is powered.
If you touch the heat sink, you may suffer from electric shock.
START
Use the correct AC input voltage.
Voltage range: 103.5-132 V
Voltage range: 198-264
(No
fluctuation from the
recommended AC voltage range
is permitted.)
Replace the fuse and disconnect
CN14 on the BOARD
ASSY.,
No
No
v
Measure the VP (+35
VDC)
at
pin 10,
CN2
of the BOARD
ASSY.,
C076
PSB/PSE.
\
+Yes
Measure the VL (+5
VDC)
at pin 1,
CN2
of the BOARD ASSY.,
C076
PSB/PSE.
,
No
&
*
END
*
END
5-5