System information
Blastware Compliance Module
___________________________________________________
4–78 Blastware Operator Manual
• Distance
Enter the first distance from the Event that you wish to begin calculating charge weight for.
The distance you enter here will be the first entry in the table, as shown in the example above.
• Increment
This value determines the increase in distance between each entry in the table. For example, if
you enter an initial distance of 500 m and set the Increment to 100 m, the table will display
the maximum charge weight at 500 m, 600 m, 700 m, etc.
To enter the Increment, click on the text box with the mouse and type in the value.
• Peak
Enter the PPV for the charge weight calculation here. Click on the text box with the mouse
and type in the value.
• Table Size
Enter the size of the table. The table can have up to 2000 entries. Click on the text box with
the mouse and type in the value.
• Command Buttons
Click Calculate to display the weight results. Click Print to print the weight table. The Output
dialog box appears, where you can choose setting to print the table, or save it to file.
xi View Data
This command displays all the numerical coordinates of the scaled distance graph.
• Copy
Use this command to copy the coordinates to third party analysis program such as Microsoft®
Excel®. Click Copy. The information transfers to the computers clipboard file. From within