System information
__________________________________________________
Blastware Compliance Module
Blastware Operator Manual 4–111
(5) Computer Port
Input a Computer Port number within the range specified (1024 – 65535) – this number must
match the number entered into the First Port field.
(6) Unit Address
This is the address of the Modem attached to the unit.
(7) Unit Port
The Auto Call Home UDP/IP software is capable of detecting the port on which each packet data
modem will communicate.
(8) Loop Test
To ensure that data is able to be sent to and from the PC to the Modem, and vice versa, perform a
Loop Test. To do this, you must disconnect the modem serial communication connector and short
the circuit of female connector pins 2 and 3, before selecting performing the Loop Test.
The Loop Test sends from 10 to 1400 bytes. It starts by sending 10 characters, or bytes, and
increments the number of characters by 10 each iteration until 1400 characters has been reached.
It then goes back to 10.
You can cancel the loop test at any time by clicking on the Cancel Loop Test button. Watch the
Message Window for the software response to the Loop Test.
i Message from the Loop Test: