System information
Blastware Advanced Module
____________________________________________________
6–50 Blastware Operator Manual
Below is a description of each column.
Charge Number:
This column is automatically generated.
Initiation Time
This column is user-defined information created from input located in the Automatic
Timeline Generation section of the Edit Timeline dialog window:
Initiation Time = (Charge Num -1) X Inter-deck Delay +
(Hole Num - 1) X Inter-hole Delay +
(Row Num - 1) X Inter-row Delay
Travel Time:
User defined column representing the time in milliseconds that a vibration takes from the
hole to the sensor.
Arrival Time:
This column represents the arrival time in ms at the sensor relative to the first arrival.
Initiation Time + Travel Time
Scale Factor:
This column represents the range, from .1 to 2, and is used to scale the amplitude of the
signature waveform, if necessary.
If you need to view the resultant data that is not shown in the window, use the Page Down key on
your keyboard to scroll through the entire timeline. After you have configured the timelines,
choose Exit and the following message is displayed:
By selecting OK, the Timeline will be applied to the event. An example is shown below: