System information
__________________________________________________
Blastware Compliance Module
Blastware Operator Manual 4–23
then the Unit Menu, Setup, and then Compliance Setup. The associated Compliance Setup
dialog which appears has several tabbed dialogs; Recording Setup, Notes, Special Setups, Printer
Setup (Series III monitors only), and Setup Files. In the lower, right hand corner of this window,
there is a message that either states “PC is not attached to a unit.” or a comparison of the operating
system version. Example: “Operating system version 4.33 on unit, 8.0 on disk.” For the best
results while using the Compliance Setup window, ensure that the two versions match. To update
the unit operating system, refer to the Reload Operating System section in this manual.
After making changes within any given tabbed Setup dialog, you have the choice to either reject
the changes by clicking on Cancel, which exits the Compliance Setup, or accept any changes by
clicking on Send to Unit, which will update the settings on the attached unit.
The dialog will initially contain the settings of the attached unit.
a. Micromate Recording Setup
Note: The Recording Setup for Series II and III is covered in the next step.
(1) Recording Mode
The record mode sets how the monitor records Events. To choose a recording mode, click on the
Recording Mode drop-down menu and select one of the following recording modes:
i Waveform
Use Waveform Record Mode to record multiple Events automatically with no dead time between
Events. The monitor records an Event, displays the results, and continues to monitor, ready to
record following Events. The monitor records all Events whose activity exceeds the preset trigger
level.
ii Waveform Manual
Use Waveform Manual Record Mode if automatic triggering is unreliable, due to excessive wind
or nearby vehicle activity, or to record the background noise level in the vicinity of a site.
Recording can be initiated from the Unit Monitor Status dialog.