Operation Manual

Command list
When the power ON command is transmitted to the projector, the power
turns on and it enters warm-up mode. When the projector's power has
turned on, a colon ":" (3Ah) is returned.
When a command is input, the projector executes the command and
returns a ":", and then accepts the next command.
If the command being processed terminates abnormally, an error message is
output and a ":" is returned.
Item Command
Power ON/OFF On PWR ON
Off PWR OFF
Signal selection Computer Auto SOURCE 1F
RGB SOURCE 11
Component SOURCE 14
HDMI SOURCE 30
Video SOURCE 41
USB Display SOURCE 51
USB SOURCE 52
LAN (EB-1776W/EB-1771W/EB-1761W
only)
SOURCE 53
A/V Mute On/Off On MUTE ON
Off MUTE OFF
A/V Mute selection Black MSEL 00
Blue MSEL 01
Logo MSEL 02
Add a Carriage Return (CR) code (0Dh) to the end of each command and
transmit.
Communications protocol
Default baud rate setting: 9600 bps
Data length: 8 bit
Parity: None
Stop-bit: 1 bit
Flow control: None
Monitoring and Controlling (EB-1776W/EB-1771W/EB-1761W Only)
127