Technical data
Table Of Contents
- Introduction
- Set Initial Conditions (SIC) Command
- IBM Emulation Mode Printer Commands
- Control Codes
- Escape Sequences
- Printer Command Parameters
- Command Structure
- Printer Command Quick Reference (IBM Emulation Mode)
- Selecting a Character Set
- Select Code Page
- Print From Code Page
- Download a Character Set
- Select Global Font
- Select Print Type Style
- Set Print Quality
- Graphics Print Modes
- Horizontal Movement
- Line Control
- Vertical Tabulation
- Line Spacing
- Set Top of Form and Page Length
- Printer Control
- Epson Emulation Mode Printer Commands
- OKI Microline Emulation Mode Printer Commands
- Using the Printer Interface
- Downloading Characters and Fonts
- Barcodes
- Code Pages
- Glossary
- Index
23
Section 2: Set Initial Conditions (SIC) Command
Use the following parameters (parms) with SIC commands that use the printer
ID of C5 and C6:
Printer
Dec Hex
2480
197 C5
2481
197 C5
2490
198 C6
2491
198 C6
Parm Description Selection Dec Hex
1 Emulation 0=No Change
1=PPDS
2=Epson
0
1
2
00
01
02
2 Panel Disable
(see Note 1)
0=No Change
1=Panel Disabled
2=Panel Enabled
0
1
2
00
01
02
3 Macro
(see Note 2)
0=No Change
1=Macro 1
2=Macro 2
3=Macro 3
4=Macro 4
255=Disable Macro
0
1
2
3
4
255
00
01
02
03
04
FF
Notes:
1
You can disable specific buttons on the operator panel. The upper 6 bits of parm 2
represent the different buttons on the operator panel. The lower 2 bits are reserved
to enable or disable the panel.
Bits 0 and 1 allow for existing panel disable functions.
To disable the panel or any of the buttons, bit 0 must be On.
The Start/Stop button and the Form Feed button are always enabled.
In the following example the Micro
Ç
and Micro
È
buttons are enabled:
Bit Off On
7. Font Disabled Enabled
6. Pitch Disabled Enabled
5. Micro
Ç
Disabled Enabled
4. Micro
È
Disabled Enabled
3. LF Disabled Enabled
2. Macro Disabled Enabled
Format ESC [ K Ln Hn init ID P1 P2
Decimal 27 91 75 04 00 254 197 00 49
Hex 1B5B4B0400FEC50031