User`s guide

ビジネスプロジェクター用 ESC/VP21 コマンド使用ガイド
ESC/VP21 Command User
s Guide for Business Projecto
rs
8. Command Details
8.1. Command table 1 (Fixed parameter)
Set commands Get commands
Parameter for set
(Return code for get)
Models Function
- ON
- OFF
All models Power ON/OFF
00: Standby as the time
of Network off”
61/81, 830/835, 740/745/732/737
760/765, 821/828, 7900/7950. S3/S4
755/750, 400W/410W, 6100/6000,
6110/6010, 1715/1710/1705/1700
1815/1810/1825, S5/X5/83/822/83+/822+
G5350/G5300/G5150/
G5100/G5000/G5200W
S6/S62/X6/W6, 1735W/1730W/1725/1720
84/85/824/825/826W
Z8000WU/Z8050W
S7/SX7/W7/S8/X8/W8
1900/1910/1915/1920W/1925W/1830
Return the Standby at
the time of Network
off status check.
01: Power on All models Return the power
status check
02: Warm up Return the warm up
status check
03: Cooling down
6100/6000, 6110/6010,
1715/1710/1705/1700, 1815/1810/1825
S5/X5/83/822/83+/822+, 260/280,
S6/S62/X6/W6
G5350/G5300/G5150/G5100/G5000/G5200W
1735W/1730W/1725/1720,
84/85/824/825/826W
Z8000WU/Z8050W, S7/X7/W7/S8/X8/W8
1900/1910/1915/1920W/1925W/1830
Return the cooling
down status check
04: Standby at the time
of Network on
7800/7850/7900/7950
8300/8350/9300, 61/81
830/835, 740/745, 760/765, 821/828
755/750, 82, 6100/6000, 1715/1705
1815/1810/1825, 83/822/83+/822+
G5350/G5300/G5150/G5100/G5000/G5200W
1735W/1725, 84/85/824/825/826W
Z8000WU/ Z8050W, S7/X7/W7/S8/X8/W8
1900/1910/1915/1920W/1925W/1830
Return the Standby at
the time of Network on
status check
PWR xx
PWR?
05: Abnormal standby 6100/6000, 1715/1710/1705/1700
1815/1810/1825, X5/822/823
G5350/G5300/G5150/G5100/G5000/G5200W
S6/S62/X6/W6, 1735W/1730W/1725/1720
84/85/824/826W
Z8000WU/ Z8050W, S7/X7/W7/S8/X8/W8
1900/1910/1915/1920W/1925W/1830
After the fixed time
passes, an abnormal
standby is returned
after this machine is
abnormally generated.