Service manual

3-4
EMP-S3
SEIKO EPSON Revision:B
3.2.1 Exterior Check
START
Upper Case Unit There should be no damage, deformation or cracking due to external force.
The Lower Case should be installed correctly.
The remote signal receiver should be clean and free from foreign materials.
Control Panel The Upper Case should be correctly installed.
No buttons should be stuck down.
Projection Lens Unit The Focus Ring should turn smoothly.
The Lens should be clean and free from damage.
Lower Case There should be no damage, deformation or cracking due to external forces.
The vent hole should be clean and free from any foreign materials.
Air Filter The Air Filter should be installed correctly.
Remove the Air Filter from the Lower Case to check that it is clean
The Intake Fan inside the Air Filter frame should be clean and free from foreign
materials.
Lamp Lid Unit The Lamp Lid should be securely attached to the Lower Case.
The Lamp Lid Detection Switch latch should be free from damage.
Lamp Assy The plastic frame should be free from any deformation, damage or discoloration
from heat. Remove the lamp inner unit to check.
The power supply connector should be free from discoloration.
The white glass surface of the lamp should be clean.
Adjustable Front Foot Unit Can the projection height be adjusted with the Foot Unit?
Interface Connectors The connectors and terminals should not be bent or discolored.
The connectors and terminals should be free from foreign materials.
AC Inlet The AC connectors should not be discolored.
The AC source socket should be free from damage.
Air Filter/Lamp Assy
Installation