Service manual
3-6
EMP-S3
SEIKO EPSON Revision:B
3.2.3 Power Supply On/Off
START
Power cord connection
Is the
indicator lit
orange?
No
Replace the Power Supply
Ballast Unit
Yes
Press the [Power] button on
the control panel. Does the
indicator flash green?
No
Press the [Power] button
on the remote control.
Yes
Does the indicator
flash green?
No
Replace tha Optical Engine
and the MA Board.
Yes
Reconnect or replace the
control panel.
To START
To START
Does the
indicator
flash green?
No
Refer to "2.9 LED Indicators" on page 2-21.
Yes
A
(To next page)