4.2.18 Removing the Power Supply Assy.
1. Remove the heat-resistant tape that secures the Power Supply Cable.
2. Remove the 1 screws that secure the Plate Power Supply Cable, and remove the Plate Power
Supply Cable.
3. Remove the Ballast Shield Plate.
4. Remove the 4 (C.B.P-TITE, 3x10, F/ZB-3C) screws that secure the Power Supply Assy.
and remove the Power Supply Assy.. Extra caution is required as one of the screws is
located underneath the Insulation Plate Ballast.
Figure 4-33.
Power Supply Unit
Isulation
Plate Ballast
Ballast Shield Plate
Plate Power Supply Cable