Display Attached Controller @E.Terminal for MC USER'S MANUAL Hardware - Additional Volume - 5.
Preface Thank you for purchasing Display Attached Controller @E.Terminal 5.7 inch model. This hardware edition of the use’s manual describes particular specifications for 5.7 inch model, and handling of the @E.Terminal. Please also read the user’s manual hardware version (FEH300). carefully. When using modules or peripheral devices, be sure to read the corresponding user’s manuals listed below. Title Manual No. Contents @E.
Safety Precaustion Be sure to read the “Safety Precautions” thoroughly before using the module. Here, the safety precaution items are classified into “Warning” and “Caution.” Warning : Incorrect handling of the device may result in death or serious injury. Caution : Incorrect handling of the device may result in minor injury or physical damage. Even some items indicated by “Caution” may also result in a serious accident. Both safety instruction categories provide important information.
Safety Precaustion Caution Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found. Failure to do so may lead to fire, damage or malfunction. For use in a facility or for a system related to nuclear energy, aerospace, medical, traffic equipment, or mobile installations, please consult your local distributor. Operate (or store) @E.Terminal under the conditions indicated in this manual and related manuals.
Safety Precaustion [General Notes] - Never bundle control cables nor input/output cables with high-voltage and large-current carrying cables such as power supply cables. Keep these cables at least 200 mm away from the high-voltage and large-current carrying cables. Otherwise, malfunction may occur due to noise. - When using @E.Terminal in an environment where a source of high-frequency noise is present, it is recommended that the FG shielded cable (communication cable) be grounded at its ends.
Revisions *Manual No. is shown on the cover. Printed on *Manual No. Revision contents Jun.
Contents Preface Safety Precautions Revisions Contents Page Section 1 General ......................................................................................... 1-1 1-1 Types ............................................................................................................................................... 1-1 1-2 System Composition ..................................................................................................................... 1-3 Section 2 Specifications .........
Section 1 General 1-1 Types - @E.Terminal for MC Product types Display size Specifications NP5M0101-2S4 5.7 inch TFT color NP5M0101-2L4 5.7 inch STN color - 320 x 240 dots, DC power supply - Controller unit - Contents of the motion control (Screen data, built in software in the controller) - @E.Terminal (No contents installed) Product types Display size Specifications NP5N0011-2S4 5.7 inch TFT color NP5N0011-2L4 5.
1-1 Types - Auxiliaries and others Names Types Specifications Battery for display unit V7-BT Replacement lithium primary battery for the V8 series USB CF card recorder USB-CFREC CF card recorder to connect with USB-Aport of V806 series Battery for controller NP8P-BT Primary lithium battery for memory data backup for controller unit SX bus terminating plug NP8B-BP For SX bus loop terminating (1 piece) SX bus expansion cabl NP1C-P3 Cable length: 300mm NP1C-P6 Cable length: 600mm NP1C-P8
1-2 System Composition The following illustration shows the system composition of @E.Terminal for MC 5.7 inch. PLC/general purpose computer RS-232C or RS-485 MJ1/MJ2 USB-B SX bus Up to 4 servos and I/O terminals each can be connected. MJ1/MJ2 "V-CP" Screen editor "V-SFT-5" (V5.4.2.0 or later) @E.Terminal for MC External PG (only No. 1 axis) USB-A FALDIC ALPHA5 "NW0H-CNV + NW0H-CA3" or commercially available USB cable [No. 1 axis] SX bus station No.: "201" [No. 2 axis] SX bus station No.
Section 2 Specifications 2-1 Specifications 2-1-1 General specifications Items Physical Operational ambient environmental temperature conditions Storage ambient temperature Operational ambient humidity Operational altitude Operational atmosphere Mechanical working conditions Electrical working conditions Pollution degree Vibration resistance Shock resistance Noise resistance Specifications NP5M0101-2S4/ 2L4, NP5N0011-2S4/ 2L4 0 to +50oC -10 to +60oC 85% RH or less (Without dew condensation, max.
2-1 Specifications 2-1-2 Display unit specifications (1) Display unit specifications Item Display device Display size Colors Display resolution (W x H) Dot pitch (W x H) Backlight Backlight life (average life of backlight only) Backlight auto OFF function Brightness adjustment Contrast adjustment Surface sheet material POWER lamp NP5M0101-2S4 NP5M0101-2L4 NP5N0011-2S4 NP5N0011-2L4 TFT color STN color 5.
2-1 Specifications (4) Interface specifications Item Modular jack 8-pin (MJ1) Modular jack 8-pin (MJ2) Applicable standards Synchronization Data length Parity Stop bit Baud rate Applications Applicable standards (Note1) Synchronization Data length Parity Stop bit Baud rate USB-B USB-A Applications Applicable standards Baud rate Applications Applicable standards Baud rate Applications Extensional communication port (CN5) USB connector (USB-A/B) Specifications RS-232C, RS-485 (2-wire connection) Asynch
2-1 Specifications (6) Drawing environment Item Drawing method Drawing tool Specifications Exclusive configuration software Name of exclusive configuration software: V-SFT-5 Personal computer: Pentium III 800 MHz or above (Pentium IV 2.0 GHz or above recommended) OS: Windows98SE/NT4.0/Me/2000/XP/XP64 Edition/Vista 32-bit Capacity of hard disk required: Free space of approx.
2-1 Specifications (8) Function performance specifications Item Specifications Screens Screen memory (FLASH memory) Switch Switch actions Max. 1024 Approx. 4.5 Mbytes (Varies depending on the font) 192 per screen Set, reset, momentary, alternate, to light (Possible to press a function switch and a switch on the display at the same time) Reverse, blink, exchange of graphics 192 per screen Pie, bar, panel meter and closed area graph:No limitation (Note: 1) Statistics and trend graphs: Max.
2-2 Dimensions and Panel Cut-out (Unit: mm) Front view ᱜ㕙࿑ Back view ⢛㕙࿑ Side view 㕙࿑ .1#&'4 75'4 41/ %#4& %27 0Q FG 176 5: $75 +0 㧗 24VDC 㧙 10. '44 741/ 470 #./ $#6 470 7 6'4/ 6'4/ 5612 75$ *Note Bottom view ਅ㕙࿑ 173.6 Note: Arrange SX bus expansion cable so that radius of bend in the cable is at least 50mm. Plug/unplug the SX bus expansion cable in the perpendicular direction.
2-3 Names and Functions ԡ 1) Display This is the display unit. 2) Power lamp (POWER) Illuminates in green when the display unit is powered on, and is operating normally. Flashes when an error occurs to the backlight (burned-out backlight, etc.). 3) Function keys Used for RUN/STOP selection, brightness adjustment and backlight ON/OFF (setting on the V-SFT-5 editor required). These switches can be used as user-defined switches in the RUN mode.
2-3 Names and Functions 8) Modular jack 1 (MJ1) Used for screen data transfer and connection with PLCs or other peripheral devices. 9) Modular jack 2 (MJ2) Used for connection with PLCs or other peripheral devices. 10) USB-B (slave port) Used for screen data transfer or connection with a PictBridge-compatible printer. 11) USB-A (master port) This is the connector where a printer or a CF card recorder “USB-CFREC” is connected. USB memory cannot be used instead of CF card.
2-4 Modular Jack (MJ1 / MJ2) Communication (RS-232C, RS-422/485) with a controller is enabled via the serial connector (CN1). Bottom view The serial connector pins correspond to signals as given below. CN1 (D-sub 9-pin, female) 8 7 6 5 4 3 2 1 MJ1 Pin No.
2-5 DIP Switches DIP switches (1 to 4) are equipped on side of the display unit. When setting the DIP switches, turn the power off. (Use USB-CFREC) DIPSW1, 2, 3 (Terminating Resistance Setting) • MJ1 can be used for RS-232C or RS-485 (2-wire) connection. For the following connections, set DIPSW1 to the ON position. - Master station for multi-link2 connection - Connection with a controller (PLC, temperature controller, etc.
Section 3 Installation 3-1 Mounting Procedure (1) Mounting procedure 1) Insert the @E.Terminal unit into the mounting panel (max. thick: 5 mm). Panel cut hole Panel cut-out deimensions (Unit:mm) Mounting panel 2) Insert four fixtures attached to the @E.Terminal unit into the mounting holes, and tighten them with the tightening screws. Tightening torque: 0.5 to 0.7 N.m Fixtures Mounting holes .1#&'4 75$ Fixture dimensions (Unit: mm) 24VDC 㧙 㧗 5: $75 +0 176 FG %27 0Q 5612 10. '44 741/ 470 #.
3-2 Power Supply Cable Wiring Electric shock hazard. Warning Shut the power off before wiring the power supply cable. (1) Power supply cable wiring .1#&'4 Grounding FG FG 75'4 41/ %#4& 㧗 24VDC 㧙 176 㧗 24VDC 㧙 .1#&'4 75$ %27 0Q %27 0Q 470 7 6'4/ 6'4/ 5612 Power supply 176 5: $75 +0 10. '44 741/ 470 #./ $#6 5: $75 +0 10. '44 741/ 470 #.
Section 4 Inspection and Maintenance 4-1 Battery Replacement When the time comes to replacement the battery, replace it for a new one even if battery error is not displayed. Also, when low battery voltage of the display unit and the controller unit is discovered, replace the battery for a new one immediately. Replacement the batteries of the display unit and the controller unit at the same time. (1)Battery replacement of controller unit 1)Turn off power supply of the @E.
4-1 Battery Replacement 3) Disconnect the battery connector. Disengage the battery from the socket by pulling the battery toward you. 4) Insert a new battery in an upright position. Check that the side with the red cable faces the right, and fit the battery on the protrusions inside the socket. 5) Plug in the battery connector and close the battery holder cover. 6) Attach the controller unit to the display unit and fix it with mounting screws at three places.
Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan E-mail: micrex-sx@fujielectric.co.jp URL: http://www.fujielectric.com/ Materials covered in this document are subject to revision due to the modification of the product.