Product specifications

12 – 41
47) Composite command for setting line feed quantity
ESC DLE H Pno A1 A2 P1 P2 P3
Code: 1B 10 48 in hexadecimal
27 16 72 in decimal
Functions:
(1) This command is one of OKI-unique commands.
(2) This command specifies the quantity of line feeding by parameter A1 (Basic LF Quantity)
and feeds paper by the specified quantity.
(3) Valid ranges and meanings of parameters
(a) Pno: Specifies the length (in bytes) of parameters following the “Pro” parameter.
The most significant bit (MSB) is voided.
00H < Pno < FFH
Pno < 05H:This command is voided and the number of bytes specified by the
“Pno” parameter are discarded.
(b) A1: Specifies a basic line feeding pitch. The most significant bit (MSB) is voided.
A1=00H, 30H 1/60" pitch (Reserved)
A1=01H, 31H 1/72" pitch
A1=02H, 32H 1/144" pitch (Reserved)
A1=03H, 33H 1/180" pitch
A1=04H, 34H 1/216" pitch
A1=05H, 35H 1/360" pitch (Reserved)
When the other parameter value is specified, the number of bytes specified by the
“Pno” parameter are discarded.
(c) A2: Specifies setting of parameters or execution of this command.
The most significant bit (MSB) is voided.
00H < A2 < FFH
A2 = even number: Sets the quantity of line feeding.
A3 = odd number: Feeds paper by the specified quantity of line feeding.
(d) P1 to P3: Specifies the quantity of line feeding according to the specified line feed
pitch (by parameter A1). Each parameter uses the lower four bits of a byte to indicate
a value of 1 to 9. (The higher four bits of each byte are ignored.)
P1: Hundreds digit of the LF quantity
P2: Tens digit of the LF quantity
P3: Ones digit of the LF quantity
The LF quantity must always be three digits long.
(4) This command can be entered anywhere on a line.
(5) This command will not set TOF.