3. Ultra Boards
Note:
The following applies to each Ultra Board used in the RS485 network
a. For each Ultra Board used: Set DIP switch 6, 7 and 8 of bank 3 to ON.
b. Perform a hard reset on each of the Ultra Boards
c. On power up, each Ultra Board will display a multi-drop address between 1
and 33.
Note: Each Ultra board is required to have a unique multi-drop address
other than 33 (33 means no address is set).
There are 3 ways to change the address
1. By using the function buttons on the Ultra Board:
See section 1.4.3 Function Buttons 1 and 2
2. By using a PS2 keyboard and the Spill Proof printer as a display:
See section 1.4.7 or 1.4.8
3. Send a configuration file to the board with a computer:
Run Flashimage.exe along with the appropriate .bix file if an appropriate
bix file is not available, create a file named C210C_Address0X.bix (where
X is the address number, 1 to 6). Then with the help of a Hex editor,
enter one byte 01 to 06 (in binary) corresponding to the desired address.
Connect the computer to the desired Ultra board using an RS232 or USB
cable
Note:
the folder must only contain the flashimage.exe file and the
C210C_Address0X.bix file.
4. Testing the Installation
a. Turn OFF the Spill Proof printer and every Ultra Board.
b. Turn ON each Ultra Board, then turn ON the Spill Proof printer
c. Within 30 seconds the Spill Proof printer will print a “Ultra Board Network
Report”. It will list all Ultra Boards connected (1-6) as well as each game which
is connected (1-6). It will also display the firmware version of the Spill Proof
printer and each Ultra Board connected.
d.
Add credit and cash out on each then press the soft meter button on
the control box. If successful, a report should be printed with the correct
results.