Epson AcuLaser CX-11N/AcuLaser CX-11NF Field Repair Guide 9/9/05
Printer Component, Software Item, LCD Display, Printer Button Page 52.
• Streaks are either continuous or evenly spaced down the page when copying and when sending faxes but not
when printing from a computer or in received faxes.
1. Dirty Scanner Calibration Strip
2. Dirty CCD Module Assembly
3. Dirty/scratched scanner bed glass
4. Defective CCD Module Assembly
Light Print
Reference AcuLaser CX11/CX11F Service Manual Section 3.4.5.4 FIP-P1
1. Photoconductor Unit not seated properly
2. Bad connection between the Photoconductor Unit and the frame.
3. Bad connections at the PWBA LV/HVPS (Low Voltage/High Voltage Power Supply)
4. PWBA LV/HVPS (Low Voltage/High Voltage Power Supply)
5. Dirty ROS Assembly
6. PWBA Main (ESS)
7. PWBA MCU
Blank Pages
Reference AcuLaser CX11/CX11F Service Manual Section 3.4.5.4 FIP-P2
1. Photoconductor Unit not seated properly
2. Bad connection between the Photoconductor Unit and the frame.
3. PWBA LV/HVPS (Low Voltage/High Voltage Power Supply)
4. Photoconductor Unit
5. Dirty ROS Assembly
6. PWBA Main (ESS)
7. PWBA MCU