Service manual
Epson AcuLaser CX-11N/AcuLaser CX-11NF Field Repair Guide 9/9/05
Printer Component, Software Item, LCD Display, Printer Button Page 54.
Ghosting (Residual Image)
Reference AcuLaser CX11/CX11F Service Manual Section 3.4.5.3 FIP-P10
1. Bad connection between the Photoconductor Unit and the frame.
2. Photoconductor Unit
3. PWBA LV/HVPS (Low Voltage/High Voltage Power Supply)
4. PWBA HVPS (High Voltage Power Supply)
5. Fuser Assembly
Grey Background
Reference AcuLaser CX11/CX11F Service Manual Section 3.4.5.3 FIP-P11
1. Bad connection between the Photoconductor Unit and the frame.
2. Sensor Assembly ADC
3. PWBA LV/HVPS (Low Voltage/High Voltage Power Supply)
4. PWBA HVPS (High Voltage Power Supply)
5. Photoconductor Unit
6. ROS Assembly
7. PWBA MCU
8. PWBA Main (ESS)
Distorted Print
Reference AcuLaser CX11/CX11F Service Manual Section 3.4.5.3 FIP-P12
1. Bad connection between the Photoconductor Unit and the frame.
2. Photoconductor Unit
3. ROS Assembly
4. PWBA Main (ESS)