User Manual June 2008 Revision 1.
Copyright 2008’ August All Rights Reserved Manual Version 1.7 The information contained in this document is subject to change without notice. We make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. We shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Safety IMPORTANT SAFETY INSTRUCTIONS 1. To disconnect the machine from the electrial power supply, turn off the power switch and remove the power cord plug from the wall socket. The wall socket must be easily accessible and in close proximity to the machine. 2. Read these instructions carefully. Save these instructions for future reference. 3. Follow all warnings and instructions marked on the product. 4. Do not use this product near water. 5. Do not place this product on an unstable cart,stand,or table.
LEGISLATION AND WEEE SYMBOL 2002/96/EC Waste Electrical and Electronic Equipment Directive on the treatment, collection, recycling and disposal of electric and electronic devices and their components. The crossed dustbin symbol on the device means that it should not be disposed of with other household wastes at the end of its working life. Instead, the device should be taken to the waste collection centers for activation of the treatment, collection, recycling and disposal procedure.
P07303 Series Customer Display User's Manual Revision History Revision Description Number 1.
Table of Contents A. 2 X 20 CUSTOMER DISPLAY 1. CHECKLIST ....................................................................................... 8 2. FEATURES ........................................................................................ 8 3. SPECIFICATION................................................................................ 9 4. INTERFACE ..................................................................................... 10 4.1. 4.2. 4.3. SPECIFICATION ..............................
P07303 Series Customer Display User's Manual B. 1 X 12 CUSTOMER DISPLAY 1. CHECKLIST ..................................................................................... 37 2. FEATURES ...................................................................................... 37 3. SPECIFICATION.............................................................................. 38 4. INTERFACE ..................................................................................... 39 4.1. 4.2. 4.3.
P07303 Series Customer Display User's Manual A. 2 x 20 Customer Display 1. Checklist G 501 mm 225 mm 191 mm 281 mm 93 mm Pole Display Module Flat Cable (DB-9P to DB-9P Flat Cable Connector) Base Unit Two Pieces of Pole Support (1x22cm, 1x9cm) Installation Guide Power Adapter 2. Features 1. Data can be display on 20 columns x 2 lines. 2. Blue–green color and large character are easy to see. 3. The DIP switches setting emulate commands mode, baud rate and international character. 4.
P07303 Series Customer Display User's Manual 3.
P07303 Series Customer Display User's Manual 4. Interface 4.1. Specification Data transmission Serial Synchronization Asynchronous Handshaking DTR / DSR MARK = -3 to –15 V (logic “1”) Signal level SPACE = +3 to +15 V (logic “0”) 4.2. Baud rates 4800,9600,19200,38400 bps Parity None, even Bit length 8 bits Stop bits 1 bit Display Base The picture below shows the configuration of the stand alone VFD Pole Display base. Figure of VFD Pole Display Base 4.3.
P07303 Series Customer Display User's Manual PWR: Power input connector from adapter Connector type: DC jack (5.5/2.
P07303 Series Customer Display User's Manual 5. Dip Switch and Software Setting 5.1. Command Type Selection SW1 ON OFF ON OFF ON OFF ON OFF 5.2. SW2 ON ON OFF OFF ON ON OFF OFF SW9 ON ON OFF OFF Demo Mode Support No Yes No Yes No No No Yes Baud Rate (bps) 4800 9600 19200 38400 Default * Parity Check Selection SW10 ON OFF 5.4. Command Type POS7300 EPSON ESC/POS ADM 787/ ADM 788 DSP800 AEDEX/ EMAX UTC/P UTC/S CD5220 Baud Rate Selection SW8 ON OFF ON OFF 5.3.
P07303 Series Customer Display User's Manual 5.5. International Character Set ID SW SW SW SW SW Character Set 4 5 6 7 11 (20h – 7Fh) 0 ON ON ON ON OFF U.S.A.
P07303 Series Customer Display User's Manual 6. Software Status Setting Commands When the system is POWER ON, it will read the DIP switch to set the Command Type, Baud Rate, Parity, Demo Mode and International Character. User can re-set the Software Status Setting Commands as following: 6.1. Baud Rate Setting Command STX 05 B n ETX ASCII Format Dec. Format Hex.
P07303 Series Customer Display User's Manual 6.3. International Character Set Setting Command STX 05 S n ETX ASCII Format Dec. Format Hex. Format Description n /Change the international character set/ STX 05 S n ETX [02] [05] [83] n [03] [02h][05h][53h] n 30h≦n≦4Fh [ 0 3 h ] Change the display international character font. Character Set (20h – 7Fh) 30h U.S.A. 31h 32h 33h 34h 35h 36h 37h 38h 39h 3Ah 3Bh 3Ch 3Dh 3Eh 3Fh 40h 41h 42h 43h 44h 45h 46h 47h 48h FRANCE GERMANY U.K.
P07303 Series Customer Display User's Manual 6.4. Command Type Setting Command /Change the command type setting/ STX 05 C n ETX [02] [05] [67] n [03] [02h][05h][43h] n 30h≦ n ≦37h [ 0 3 h ] This command will change the command type and initialize the display. The display emulation mode is based on DSP800/ ESC/ ADM 787/ POS7300/ AEDEX/ UTC/ CD5220 mode. STX 05 C n ETX ASCII Format Dec. Format Hex. Format Description n 30h 31h 32h 33h 6.5.
P07303 Series Customer Display User's Manual 7.
P07303 Series Customer Display User's Manual Command List Table – 2 POS730 CD522 EPSON UTC/ UTC/ ADM78 DSP80 AEDEX 0 0 D101 S P 8 0 Upper line message continuous scroll Bottom line message scroll continuously Message vertical down scroll continuously Message vertical upper scroll continuously Carriage return Line feed Back space Horizontal tab Command type select Upper line message scroll once pass Change attention code Two line display Clear upper line and move cursor to upper left-end position Clear bot
P07303 Series Customer Display User's Manual 8. Command Details 8.1.
P07303 Series Customer Display User's Manual POS7300 Standard Mode Command List-2 Command BS HT LF HOM CLR CR CAN ESC = n Code (hex) 08 09 0A 0B 0C 0D 18 1B 3D n Function Description Back space Horizontal tab Line feed Move cursor to home position Clear display screen Carriage return Clear cursor line, and clear string mode Select peripheral device, display or printer ¾ n = 1~3 n = '1': enable printer only n = '2': enable display only n = '3': enable both of printer and display 20
P07303 Series Customer Display User's Manual 8.2.
P07303 Series Customer Display User's Manual CD5220 Standard Mode Command List-2 Command Code (hex) ESC W s x1 x2 1B 57 s x1 x2 y y CLR CAN ESC * n US X n ESC _ n 0C 18 1B 2A n 1F 58 n 1B 5F n ESC f n 1B 66 n ESC c n 1B 63 n ESC = n 1B 3D n Function Description Set or cancel the window range at horizontal scroll mode ¾ 1 ≦ x1 ≦ x2 ≦ 14h, for columns location. ¾ y = 1~2, for lines location.
P07303 Series Customer Display User's Manual 4. The parameter of the code table control by command “ESC c n”.
P07303 Series Customer Display User's Manual 8.3. UTC Standard Mode Command List Command BS HT LF CR DLE n 08 09 0A 0D 10 n DC1 DC2 DC3 DC4 US ESC d 11 12 13 14 1F 1B 64 8.4. Code (hex) Function Description Back space Horizontal tab Line feed Carriage return Display position ¾ n = 0 ~ 27h, for location.
P07303 Series Customer Display User's Manual 8.5. AEDEX/EMAX Mode Command List Command Code (hex) ! # 4 [DATA] 21 23 34 [DATA] 0D CR ! # 5 h h : m m 21 23 35 h h ':' m m 0D CR ! # 8 n m CR 21 23 38 n m 0D ! # 9 [DATA] CR ! # 6 [DATA] CR 8.6.
P07303 Series Customer Display User's Manual 8.7.
P07303 Series Customer Display User's Manual 8.8. EPSON ESC/POS Command List EPSON ESC/POS Command List-1 Command Code (hex) Function Description US r n 1F 72 n Select/cancel reverse character. ¾ n = 00,01 US MD1 1F 01 Specify overwrite mode. US MD2 1F 02 Specify vertical scroll mode. US MD3 1F 03 Specify horizontal scroll mode. CAN 18 Clear cursor line ESC # n 1B 23 n Command type select ¾ n = 30h ~ 38h US # n x 1F 23 n x Turn annunciator on/off.
P07303 Series Customer Display User's Manual EPSON ESC/POS Command List-2 Command Code (hex) Function Description US ^ n m 1F 5E n m Execute and quit macro. It’s an interval of n between the two words. It’s an interval of m between the two strings.
P07303 Series Customer Display User's Manual 9. Character Set 9.1. Character Code 20H – 7FH 9.1.1 International Character Sets Character Code Number Country Hex 23 24 40 5B 5C 5D 5E 60 7B Dec 35 36 64 91 92 93 94 96 123 124 125 126 # # # £ # # # Pt # # # # # $ $ $ $ $ ¤ $ $ $ ¤ $ $ $ @ à § @ @ É @ @ @ É É @ @ [ ° Ä [ Æ Ä ° ¡ [ Æ Æ [ [ \ ç Ö \ Ø Ö \ Ñ ¥ Ø Ø \ \ ] § Ü ] Å Å é ¿ ] Å Å ] ] ^ ^ ^ ^ ^ Ü ^ ^ ^ Ü Ü ^ ^ ` ` ` ` ` é ù ` ` é é ` ` { é ä { æ ä à ¨ { æ æ { { U.S.
P07303 Series Customer Display User's Manual 9.2. 9.2.1 80h 90h A0h B0h C0h D0h E0h F0h 9.2.2 80h 90h A0h B0h C0h D0h E0h 9.2.
P07303 Series Customer Display User's Manual 9.2.4 Katakana for Japan 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h α β γ ⊿ є η θ λ μ π ρ σ τ Ф Ω ∑ £ § IE IR ∫ x Ā -1 ² ³ x ½ 1/ √ ± ■ 。 「 」 、 ‧ 90h A0h B0h C0h D0h E0h F0h 9.2.
P07303 Series Customer Display User's Manual 9.2.7 80h 90h A0h B0h C0h D0h E0h F0h 9.2.
P07303 Series Customer Display User's Manual 9.2.10 80h 90h A0h B0h C0h D0h E0h F0h 9.2.11 80h 90h B0h C0h D0h E0h F0h 9.2.
P07303 Series Customer Display User's Manual 9.2.13 80h 90h A0h B0h C0h D0h E0h F0h 9.2.14 80h 90h A0h B0h C0h D0h E0h F0h 9.2.
P07303 Series Customer Display User's Manual 9.2.16 Windows-1253 (Greek) 00h 01h 02h 03h 04h 05h 06h 07h 08h 09h 0Ah 0Bh 0Ch 0Dh 0Eh 0Fh 80h 90h A0h B0h C0h D0h E0h F0h 9.2.17 80h 90h A0h B0h C0h D0h E0h F0h 9.2.
P07303 Series Customer Display User's Manual 10. Display Module Dimension 200mm 0.38o 176mm 39mm 70mm 158.6mm 5.25mm 0.85mm 0.25mm 1.05mm 0.25mm 9.0mm 9.5mm 1.5mm 22.5mm 1.5mm 1.5mm 6.
B. 1 x 12 Customer Display 1. Checklist G 501 mm 225 mm 191 mm 281 mm 93 mm Pole Display Module Flat Cable (DB-9P to DB-9P flat cable connector) Base Unit Two pieces of pole support (1x22cm, 1x9cm) Installation guide Power Adapter 2. Features 1. 2. 3. 4. Data can be display on 12 columns x 1 line. Blue–green color and large character are easy to see. Command emulation modes include: POS7300, EPSON ESC/POS. Provides an interface based in RS-232C, and RS232C baud rate 9600 bps.
P07303 Series Customer Display User's Manual 3. Specification NO Item Description 1 Display method Vacuum fluorescent display 2 Number of character 3 Character font 7 segment 4 Display color Blue green 5 Brightness 700 cd /㎡ 6 Character type 10 numeric 7 Character size dot matrix 17.0 x 5.4 mm 8 Power supply 9 Power consumption 3-6W 10 MTBF 25000 hours (power on time) 11 Panel dimensions 224 (W) x 93 (H) x 50(D) mm 12 Support dimensions 13 Base dimensions 19.
P07303 Series Customer Display User's Manual 4. Interface 4.1. Interface Specification Data transmission Serial Synchronization Asynchronous Handshaking DTR / DSR MARK = -3 to –15 V (logic “1”) Signal level SPACE = +3 to +15 V (logic “0”) 4.2. Baud rates 9600 bps Parity None Bit length 8 bits Stop bits 1 bit Display Base Below illustrate the configuration of Stand alone VFD Pole Display base. Figure of VFD Pole Display Base 4.3.
P07303 Series Customer Display User's Manual PWR: Power input connector from adapter Connector type: DC jack (5.5/2.
P07303 Series Customer Display User's Manual 5. Command List Table Command List Table – 1 Command ESC @ ESC D ESC O m Code (Hex) 1B 40 1B 44 1B 4F m ESC B m 1B 42 m ESC [ D SO NULL K ESC [ C SI NULL M ESC [ H HOM ESC [ L CR LF NULL G ESC [ R NULL O ESC [ K ESC l x y ESC P x y 1B 5B 44 0E 00 4B 1B 5B 43 0F 00 4D 1B 5B 48 0B 1B 5B 4C 0D 0A 00 47 1B 5B 52 00 4F 1B 5B 4B 1B 6C x y 1B 50 x y CLR CAN . 0C 12 2E ESC .
P07303 Series Customer Display User's Manual Command List Table – 2 Command Code (Hex) Function Description ESC Q A 1B 51 41 [DATA] 0D Set the string display [DATA] CR ¾ Maximal [DATA] length is 12 ESC F A [DATA] 1B 46 41 [DATA] 0D CR ESC - m 1B 2D m Set left-most dash ON or OFF ¾ m= 1 ~ 2 ESC _ n 1B 5F n Set cursor ON or OFF ¾ n= 0 ~ 1 US E n 1F 45 n Blink display screen ¾ n = 00h~FFh n = 0 for disable blink BS 08 Back space 42
P07303 Series Customer Display User's Manual 6. Command Details Command Details – 1 ESC [ C ASCII Format Dec. Format Hex. Format Description SI ASCII Format Dec. Format Hex. Format Description ESC [ H ASCII Format Dec. Format Hex. Format Description ESC [ L ASCII Format Dec. Format Hex. Format Description CR ASCII Format Dec. Format Hex. Format Description LF ASCII Format Dec. Format Hex. Format Description ESC [ R ASCII Format Dec. Format Hex.
P07303 Series Customer Display User's Manual Command Details – 2 ESC [ K ASCII Format Dec. Format Hex. Format Description ESC l x y ASCII Format Dec. Format Hex. Format Description : : : : ESC P x y ASCII Format Dec. Format Hex. Format Description : : : : CLR ASCII Format Dec. Format Hex. Format Description CAN ASCII Format Dec. Format Hex. Format Description . ASCII Format Dec. Format Hex. Format Description ESC @ ASCII Format Dec. Format Hex.
P07303 Series Customer Display User's Manual Command Details – 3 ESC O m ASCII Format Dec. Format Hex. Format Description : : : : ESC B m ASCII Format Dec. Format Hex. Format Description : : : : ESC [ D ASCII Format Dec. Format Hex. Format Description SO ASCII Format Dec. Format Hex. Format Description ESC . x m ASCII Format Dec. Format Hex.
P07303 Series Customer Display User's Manual Command Details – 4 ESC ‘ x m ASCII Format Dec. Format Hex. Format Description / Set the comma mark ON or OFF on specified position / : : : : ESC Q A [DATA] CR ASCII Format : Dec. Format : Hex. Format : Description : ESC F A [DATA] CR ASCII Format : Dec. Format : Hex. Format : Description : ESC - m ASCII Format Dec. Format Hex. Format Description : : : : ESC _ n ASCII Format Dec. Format Hex.
P07303 Series Customer Display User's Manual Command Details – 5 US E n ASCII Format Dec. Format Hex. Format Description BS ASCII Format Dec. Format Hex. Format Description NULL K ASCII Format Dec. Format Hex. Format Description NULL M ASCII Format Dec. Format Hex. Format Description NULL G ASCII Format Dec. Format Hex. Format Description NULL O ASCII Format Dec. Format Hex. Format Description STX 05 V 01 ASCII Format Dec. Format Hex.
P07303 Series Customer Display User's Manual 7. Character Set 0 1 2 3 4 5 6 7 8 9 A/a B/b C/c D/d E/e F/f G/g H/h I/i J/j K/k L/l M/m N/n O/o P/p Q/q R/r S/s T/t U/u V/v W/w X/x Y/y Z/z Space - = / [ ] _ Note: ¾ Undefined characters will be displayed as a space character.
P07303 Series Customer Display User's Manual 8.
(2 x 20 Customer Display and 1 x 12 Customer Display) Appendix A - Command Details A.1. Overwrite mode In this mode, the cursor will move towards the right and begin from the upper left position. When the cursor has reached the end of the upper line, the cursor will move down to the bottom left position to continue. When the cursor has reached the end of the bottom line, it will move to up the upper left position and overwrite the previous characters. A.2.
P07303 Series Customer Display User's Manual Move the cursor to the right. When the cursor has reached the right-end, this command operates differently depending on the display mode. Overwrite mode: When the cursor has reached the right-end of the lower line, it will continue to the left-end of the upper line and overwrite previous characters. When it has reached the right-end of the upper line, it will continue to the right-end of the lower line.
P07303 Series Customer Display User's Manual A.14. Move cursor to specified position The cursor will be moved to column x on line y. A.15. Initialize display The data in the input buffer will be cleared and reset from default. A.16. Reset the window Reset the window on the display. When s=0, the window is cancelled (values: x1, x2, and y are not required.) When s=1, the window will be reset (values: x1, x2, and y are required.
P07303 Series Customer Display User's Manual Appendix B - Control Code Set HEX 00H 01H 02H 03H 04H 05H 06H 07H 08H 09H 0AH 0BH 0CH 0DH 0EH 0FH CODE NULL SOH, MD1 STX, MD2 ETX, MD3 EOT, MD4 ENQ, MD5 ACK, MD6 BEL, MD7 BS, MD8 HT LF VT, HOM FF, CLR CR SO, SLE1 SI, SLE2 HEX 10H 11H 12H 13H 14H 15H 16H 17H 18H 19H 1AH 1BH 1CH 1DH 1EH 1FH 53 CODE DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS, SF1 US, SF2